39
2
21/01/16 Rev:3.0.0
English
PARAMETERS
Timer service 1
<
200
> (
h)
Timer service 2
<
400
>
(h)
Timer Dust max
<
032
> (
h)
11.5.2 Set up dust collection
In this menu you can modify the kind of dust collection (dust bin or bag) used by the central vacuum
unit.
1
Press the
Right
and
Left
arrows to select
the kind of dust collection and press
En-
ter
the activate the chosen function.
Press
Esc
to con
fi
rm the choice and exit
the menu.
11.5.3 Set up parameters
In this menu you can modify the parameters relating to the functioning of the central vacuum unit set
by the construction company.
CAUTION:
These modi
fi
cations may alter the correct functioning of the product. Therefore it is advisa-
ble to contact the construction company before modifying any parameter.
PARAMETERS
Alarm bag 1
<
164
>
mbar
Alarm bag 2
<
180
>
mbar
Alarm bag 3
<
240
>
mbar
PARAMETERS
Alarm fi lter 1
<0
85
>
mbar
Alarm fi lter 2
<
085
>
mbar
Alarm fi lter 3
<
100
>
mbar
Press the
Up
and
Down
arrows to select
the parameter.
Press the
Left
and
Right
arrows to mo-
dify the parameter.
Press
Esc
to con
fi
rm the modi
fi
cation
and exit the menu.
1
;
Selection is active
Selection is not active
DUST COLLECTION
;