background image

1 - GENERAL INFORMATION

1.1 The User Guide

The user guide is a fundamental document written by the builder, to be considered
an  integral  part  of  the  central  suction  unit.  In  case  of  resale,  offering  or  lease  to
third  parties,  the  user  guide  must  be  handed  over  to  the  new  user  or  to  the  new
owner.  The  builder  must  be  informed  about  any  ownership  change.
We recommend storing and keeping the user guide throughout the whole operating
life of the suction unit.
The main purpose of the user guide is to provide a correct knowledge of the user
mode in order to exploit the best performance and to maintain the central suction
unit at its best working and security conditions.
It  is  absolutely  forbidden  to  duplicate,  copy  or  release  totally  or  part  of  this  user
guide  without  previous  written  authorization  by  TECNOPLUS  Srl,  owner  of  the
trademark SISTEM-AIR.

1.2 Safety and security precautions

Read carefully any information written in this user guide regarding installation, use
and maintenance of the central suction unit.

Never use inappropriately the central suction unit.
Never let the children get near the central suction unit when it is working and never
let  the  children  play  with  the  suction  inlets  or  with  the  suction  unit.
Unplug the central suction unit when:

 

The power supply cable is worn out or damaged

 

The central suction unit has been exposed to the inclemency of the weather or to excessive moisture.

 

The central suction unit has been damaged by an impact or the external container has been damaged

 

The central suction unit requires any repairing or overhauling.

Always  wear  protection  gloves  and  mask  when  carrying  out  any  maintenance
operation, and  when  unloading the  dust container  or replacing/cleaning the  filter.
Use only SISTEM-AIR original spare parts.
Never  use  the  suction  unit to remove  textile stuff, big-size  bits and  pieces  of any
material, burning coals or ashes.

Use  the  suction  unit  only  with  the  special  filter  cartridge  correctly  assembled.
Never  block  the  air  exhaust  pipes  and  the  cooling  inlets  of  the  motor.
Never touch the suction accessories with any part of the body.
Use only one inlet at a time.
If you are not going to use the central suction unit for a short time, it is advisable to
switch  it  off.   If  you  are  not  going  to  use  the  central  suction  unit  for  an  extended
period  of  time,  it  is  advisable  to  cut  it  off  from  the  mains  power  supply.

2

TA-TE 02/04-01

Installation, use and maintenance guide

Содержание 3107.0TA

Страница 1: ...the pipe network 17 4 5 Electric system 18 5 How to use the central suction unit 5 1 Starting of the suction unit 19 5 2 Use of the suction unit 19 6 Maintenance 6 1 Programmed maintenance 20 6 2 Unl...

Страница 2: ...ction unit when it is working and never let the children play with the suction inlets or with the suction unit Unplug the central suction unit when The power supply cable is worn out or damaged The ce...

Страница 3: ...of the central suction unit Technical Service Provider and After Sales Service Authorized Technical Assistance Center 1 3 Identification plate SISTEM AIR ITALY Tel 39 0381650082 Fax 39 0381650120 Typ...

Страница 4: ...o move the suction unit to the location selected for the installation If necessary use a trolley to move the suction unit or ask somebody to help you Arrange the cardboard box on the floor with the op...

Страница 5: ...the straps Remove the upper cardboard protection lift the suction unit and arrange it on the floor in a vertical position Remove the dust protection bag Take out all the accessories contained in the...

Страница 6: ...the Builder s trademark One user guide for correct installation use and maintenance One exhaust silencer made of plastic for the air exhaust 6 Installation use and maintenance guide Check that the suc...

Страница 7: ...ion hose The SISTEM AIR central suction unit must be installed in a separated room for example in a storage room in a garage or in another service room and is connected to the suction pipes network Th...

Страница 8: ...ge 3 3 Compliance with the requirements and the relevant provisions of the EEC Directives in force The suction units model SA which are the object of this user guide fully comply with the requirements...

Страница 9: ...Activa Line are equipped with computers which control the maintenance cycles and indicate when it s time to carry out maintenance operations Soundproofing top cover Electronic card supporting panel Po...

Страница 10: ...3 5 Technical features See picture and table 10 Installation use and maintenance guide TA TE 02 04 01...

Страница 11: ...11 TA TE 02 04 01 Installation use and maintenance guide...

Страница 12: ...to carry out motor servicing 6 key It is used during programming operations to increase the value indicated on the display 7 key It is used during programming operations to decrease the value indicat...

Страница 13: ...o be installed in a multistorey building the suction unit must be located at the lowest level of the building The suction unit can be installed in a service room for example in a garage or in a storag...

Страница 14: ...m DX right to SX left model The suction units included in the TECNO line are usually delivered suction and exhaust pipes connections assembled on the right side of the unit DX model when necessary it...

Страница 15: ...uide Fix the adhesive plate supplied with the central suction unit 7 6 5 8 Plug the card cable in the special guides and assemble the dustproof spongy disk to seal the opening Only for TECNO Activa Li...

Страница 16: ...You must use the special frame provided with the suction unit and the special screws to hang the central suction unit firmly and permanently to a wall Remember that the suction unit must hold up the e...

Страница 17: ...fitting to connect the suction unit to the suction hose Use the correct fitting to connect the suction unit to the air exhaust pipe Stick the silencer on the exhaust pipe near the exhaust grid 3 1 2...

Страница 18: ...electric system not in compliance with the regulations in force Follow the instructions to carry out this operation correctly see picture Connect the starting signal input cable Connect the exit cable...

Страница 19: ...of the hose in the suction inlet The suction system will start automatically 19 TA TE 02 04 01 Installation use and maintenance guide 5 HOW TO USE THE CENTRAL SUCTION UNIT After finishing the cleaning...

Страница 20: ...n demand warns the user by means of a remote control system when it is necessary to carry out maintenance operations or connect directly to the service provider if a maintenance contract has been prev...

Страница 21: ...al suction unit press the RESET key only for TECNO Activa Central suction unit Disassemble the dust container Remove the conveyor cone Unload the dust container Assemble the conveyor cone Reassemble t...

Страница 22: ...RESET key only for TECNO Activa Central suction unit 6 3 Replacement of the filter cartridge Disassemble the dust container Unscrew the locking handle Replace the filter cartridge Screw the locking h...

Страница 23: ...urface of the cartridge 7 SERVICING 7 1 Servicing criteria It is strictly forbidden to operate on the central suction unit to carry out any maintenance or servicing not mentioned and therefore not all...

Страница 24: ...tion Modifying the values above is a very simple procedure but it requires a minimum of attention and all sequences should be followed meticulously in order to be effective If you need additional info...

Страница 25: ...ne on 3 The led and will appear together with a bar on the monitor Now we are ready to enter the PIN 4 Press the button A will appear on the display 5 With the buttons choose the first number you wish...

Страница 26: ...Press the button The led DUST CONTAINER UNLOADING ALARM will switch off and the led MOTOR MAINTENANCE ALARM will switch on On the display the number 1 will appear 18 With the buttons and choose a num...

Страница 27: ...l switch on The programmed number of hours will be displayed see reference values at pag 23 5 DISPLAY OF THE DUST CONTAINER UNLOADING TIMING press the button The led will switch off and the led DUST C...

Страница 28: ...see reference values at pag 23 4 CHANGE OF THE DUST CONTAINER UNLOADING TIMING Press the button until the DUST CONTAINER led switches on The programmed number of hours will be displayed Press buttons...

Страница 29: ...ger human health or well being as well as the environment if handled improperly You must be acquainted with sites companies authorized to collect and dispose of used parts and materials The disposal a...

Страница 30: ...uction system are obstructed The air exhaust is obstructed The microswitch of a single inlet does not work Possible corrective measures Plug in the power supply cable Press the start push button Plug...

Отзывы: