Siser TS DUE Скачать руководство пользователя страница 8

  

 

 

This manual is the property of SISER S.r.l., any even partial reproduction is forbidden  

Mod. PRD 22 rev.2   -   last updating: 01/2015 

 

6. Mounting, Transport and Mounting Location 

The installation of the transfer press must only be performed by suitably qualified personnel, as the electrical 

connections must comply with local regulations.  

Before mounting the transfer press prepare a suitable mounting location. Handle the package containing the 

transfer press with care and with the aid of suitable tools. As the transfer press is heavy, the mounting should 

be performed by two people. 

For the mounting location you need a stable table with a height of approximately 70 cm. Fixing the unit's feet 

to the table top is a good way to increase the safety of the unit particularly if the work table is mobile.  

7. Electrical Connection 

The transfer press must be mounted in a room featuring a power supply system approved by local authorities 

and complying with effective safety regulations for electric devices.  

The available power supply lines must have a cross section sufficient for the transfer press's energy demand 

of 2 kW, preferably in its own power circuit. The characteristic values of the power supply system must comply 

with the characteristics of the heat transfer press. Please check the values stated on the label. 

The  coloured  conductor  markings must  be  carefully  complied  with and  the  transfer  press must  be  earthed. 

Please refer to EN 60439 

– 1 (CEI 17-13/1). 

The power socket must have an electric protective earthing and a residual-current-operated protective device 

(RCD) disconnecting the circuit if the residual current exceeds 30 mA. 

Do not use cables with damaged insulation. It is inadvisable to use extension cords.  

Remove the plug from the power socket before starting any maintenance or repair work, in particular 

if it is necessary to open the box of the control panel or to perform work on the heating elements. 

The graphic symbol „High-Tension“ signalises a serious danger and is attached on the box of the control panel 

and  on  top  of  the  heating  elements.  Switch  off  the  master  switch  before  exchanging  or  removing  heating 

elements.  

 

8. Directions for Use 

Please  note  the  risks  involved  in  using  a  transfer  press  mentioned  in  paragraph  4  of  this  manual,  in 

particular 

 

the risk of squashing your hands in between the plates 

 

the risk of an electric shock 

 

the risk of burning your hands and arms on the heating plates 

Wear protective gloves to avoid the risk of getting burned.  
 
 

Содержание TS DUE

Страница 1: ...ual is the property of SISER S r l any even partial reproduction is forbidden Mod PRD 22 rev 2 last updating 01 2015 OPERATING INSTRUCTIONS FOR PNEUMATIC Heat Transfer Press TS DUE with interchangeabl...

Страница 2: ...sure that all operators of the transfer press have understood all instructions and graphic symbols labelled on the press Accidents can also be avoided by strictly following the safety regulations acc...

Страница 3: ...The reclaim of defective parts after their replacement is at the discretion of Siser Parts needing to be replaced because of maintenance wear or carelessness are not included in this warranty Any clai...

Страница 4: ...cable between heating plate and instrument box Now untighten the clamping element of the heating plate suspension remove the heating plate with care and put it down on a safe even surface Fit the bent...

Страница 5: ...just underneath the supporting plates Now you can swap the present supporting plate for a plate of your choice and fix the new plate by tightening the fixing screws It is not necessary to swap the he...

Страница 6: ...This manual is the property of SISER S r l any even partial reproduction is forbidden Mod PRD 22 rev 2 last updating 01 2015 TS DUE with plates cm 15x38 TS DUE with cap set...

Страница 7: ...d to touch the lower supporting plates when closing the press or printing the textile as these operations involve a risk of getting squashed and burned It is strongly recommended that only one person...

Страница 8: ...wer circuit The characteristic values of the power supply system must comply with the characteristics of the heat transfer press Please check the values stated on the label The coloured conductor mark...

Страница 9: ...nto its original position 8 Adjust the real printing pressure by turning the pressure controller on the right upper side of the press To adjust the pressure turn it clockwise to increase the pressure...

Страница 10: ...or use as soon as the desired temperature is reached It is always possible to check time and temperature by tapping the S button Working programms With the new control board TS2 3P 4 different program...

Страница 11: ...with the control board If 000 appears on the display and the light blinks followed by an acoustic signal the temperature ranges about 15 C because of a default The control board has to be checked 9 M...

Страница 12: ...dustrial unit All applicable laws concerning the disposal of industrial machinery in the country of the user must be followed Disconnect the unit from the power supply and dismantle it Sort the parts...

Страница 13: ...cable run 15 supporting plate support 16 ferrule 17 speed controller on request 18 heating plate 19 teflon rod 20 heating rods 5 pcs 475 x 45 mm W 400 V 220 21 temperature sensor 1m long 22 teflon cov...

Страница 14: ...nual is the property of SISER S r l any even partial reproduction is forbidden Mod PRD 22 rev 2 last updating 01 2015 12 Exploded View Exploded view of transfer press with order numbers 13 Electronic...

Страница 15: ...This manual is the property of SISER S r l any even partial reproduction is forbidden Mod PRD 22 rev 2 last updating 01 2015...

Страница 16: ...This manual is the property of SISER S r l any even partial reproduction is forbidden Mod PRD 22 rev 2 last updating 01 2015 14 Electronic Diagram board S2...

Страница 17: ...SISER S r l any even partial reproduction is forbidden Mod PRD 22 rev 2 last updating 01 2015 14 Pneumatic Diagram 1 filter controller 2 mini controller 3 electronic valve 4 control of air flow 5 end...

Отзывы: