This manual is the property of SISER S.r.l., any even partial reproduction is forbidden
Mod. PRD 22 rev.2 - last updating: 01/2015
TS DUE with plates cm. 15x38
TS DUE with cap set
Страница 1: ...ual is the property of SISER S r l any even partial reproduction is forbidden Mod PRD 22 rev 2 last updating 01 2015 OPERATING INSTRUCTIONS FOR PNEUMATIC Heat Transfer Press TS DUE with interchangeabl...
Страница 2: ...sure that all operators of the transfer press have understood all instructions and graphic symbols labelled on the press Accidents can also be avoided by strictly following the safety regulations acc...
Страница 3: ...The reclaim of defective parts after their replacement is at the discretion of Siser Parts needing to be replaced because of maintenance wear or carelessness are not included in this warranty Any clai...
Страница 4: ...cable between heating plate and instrument box Now untighten the clamping element of the heating plate suspension remove the heating plate with care and put it down on a safe even surface Fit the bent...
Страница 5: ...just underneath the supporting plates Now you can swap the present supporting plate for a plate of your choice and fix the new plate by tightening the fixing screws It is not necessary to swap the he...
Страница 6: ...This manual is the property of SISER S r l any even partial reproduction is forbidden Mod PRD 22 rev 2 last updating 01 2015 TS DUE with plates cm 15x38 TS DUE with cap set...
Страница 7: ...d to touch the lower supporting plates when closing the press or printing the textile as these operations involve a risk of getting squashed and burned It is strongly recommended that only one person...
Страница 8: ...wer circuit The characteristic values of the power supply system must comply with the characteristics of the heat transfer press Please check the values stated on the label The coloured conductor mark...
Страница 9: ...nto its original position 8 Adjust the real printing pressure by turning the pressure controller on the right upper side of the press To adjust the pressure turn it clockwise to increase the pressure...
Страница 10: ...or use as soon as the desired temperature is reached It is always possible to check time and temperature by tapping the S button Working programms With the new control board TS2 3P 4 different program...
Страница 11: ...with the control board If 000 appears on the display and the light blinks followed by an acoustic signal the temperature ranges about 15 C because of a default The control board has to be checked 9 M...
Страница 12: ...dustrial unit All applicable laws concerning the disposal of industrial machinery in the country of the user must be followed Disconnect the unit from the power supply and dismantle it Sort the parts...
Страница 13: ...cable run 15 supporting plate support 16 ferrule 17 speed controller on request 18 heating plate 19 teflon rod 20 heating rods 5 pcs 475 x 45 mm W 400 V 220 21 temperature sensor 1m long 22 teflon cov...
Страница 14: ...nual is the property of SISER S r l any even partial reproduction is forbidden Mod PRD 22 rev 2 last updating 01 2015 12 Exploded View Exploded view of transfer press with order numbers 13 Electronic...
Страница 15: ...This manual is the property of SISER S r l any even partial reproduction is forbidden Mod PRD 22 rev 2 last updating 01 2015...
Страница 16: ...This manual is the property of SISER S r l any even partial reproduction is forbidden Mod PRD 22 rev 2 last updating 01 2015 14 Electronic Diagram board S2...
Страница 17: ...SISER S r l any even partial reproduction is forbidden Mod PRD 22 rev 2 last updating 01 2015 14 Pneumatic Diagram 1 filter controller 2 mini controller 3 electronic valve 4 control of air flow 5 end...