  (3) Make sure all the stand casters are locked or fixed in position. 
  (4) Keep the working area clean from obstacles.

5. During Operation
  (1) Always keep your fingers, hair, or clothing away from the moving components and moving area. Do not place 

your personal belongings on the machine.

  (2) The machine is designed to run at high speed. Always keep your hands away from the moving area. Do not 

resume the work cycle until the machine stops completely.

  (3) Be careful not to be caught by the machine or components when removing or resetting the machine.
  (4) To avoid accident caused by abrupt start, when performing service on the motor or belt, make sure the power is 

off and the machine stops completely.

  (5) A servo motor is silent as the machine stops. Be sure to turn off the power to avoid an abrupt start. (6) Always 

keep the fan and airway of the power cabinet clean from any obstacle.

6. Lubrication
  (1) Apply only qualified oil and grease onto the parts as instructed in the manual.
  (2) If the lubricant contacts your eye or body, wash it off immediately. Consult a medical care if necessary. 
  (3) If the lubricant goes into your body accidentally, go to the nearby medical care immediately.

7. Service
  (1) Only a certified engineer/technician is allowed to perform service to the machine, including adjusting and 

repairing. Use only genuine parts for replacement. Our company assumes no responsibility/liability for any 
accident caused by improper repair or adjustment, or the use of any parts other than genuine one.

  (2) Only a certified technician or authorized engineer is allowed to repair or maintenance the electric system.
  (3) When performing service to air-driven parts, like an air cylinder, first disconnect the air supply and expel the air 

completely to avoid abrupt start.

  (4) Check all screws and nut are fixed well after adjusting and replacement.
  (5) A periodical cleaning is necessary. Make sure the power is off and the machine stops completely before cleaning. 
  (6) If the machine functions poorly or abnormally, stop the operation and turn off the power. Contact the authorized 

dealers or us to request for a technical service support.

  (7) When there is a fuse failure, turn off the power, find out the cause of the failure and apply solution to it, then 

replace with a new one with the same spec.

  (8) Periodically check and clean the fan airway and the cable/wiring.

8. Working Environment
  (1) The machine should be free from the affection of electro-magnetic wave.
  (2) The power supply should be in good and reliable condition, the fluctuation of rated voltage should be less than 

10%.

  (3) Always check the air pressure and quality. Some extra device might be needed if the supply is not reliable.
  (4) The machine is designed to be used with ambient temperature 5

°

 C ~ 35

°

 C, relative humidity 35%~85%.

  (5) To protect the electronic components and for safety cause, when there is a frost resulting from a dramatic 

temperature rise, disconnect the power and wait until it dry completely.

  (6) For safety cause, when there is a thundering or lightening, stop the operation and disconnect the power supply. 
  (7) Do not use TV or radio nearby the machine as to avoid interference.
  (8) Apply necessary protection during operation. Follow applicable regulations set by local administration.
  (9) For disposal of packages, lubricant, and product, please follow the applicable regulations set by local 

administration.

Содержание ASK-ASM100

Страница 1: ...ASK ASM100 ORIGINAL INSTRUCTIONS BOOK PARTS LIST...

Страница 2: ......

Страница 3: ...ENGLISH ENGLISH...

Страница 4: ...ear to avoid injury High speed moving area Stay away and keep clear to avoid injury CAUTION Moving parts may cause in jury Operate with safety devices Turn off main switch before threading changing bo...

Страница 5: ...modification 1 It is prohibited to use the machine for any application other than its original intention or in any manner other than that prescribed in the instruction manual 2 Never modify or alter t...

Страница 6: ...se you need to leave the machine on a surface temporarily for service make sure the surface is strong enough to hold the weight 2 If casters are applied to the table stand adopt casters with a locking...

Страница 7: ...intenance the electric system 3 When performing service to air driven parts like an air cylinder first disconnect the air supply and expel the air completely to avoid abrupt start 4 Check all screws a...

Страница 8: ...RUCTION FOR AMS SERIES Power Switch Always turn off the power when 1 Performing service 2 The machine is left unattended between works Parts moving area Always keep the moving area clean and free from...

Страница 9: ...ely The START button will flicker to indicate the status Power Cabinet Only certified engineers or technicians are allow to open the power cabinet for service purpose Turn off the power and disconnect...

Страница 10: ...EX PAGE SPECIFICATION 1 INSTALLATION 2 OPERATION FLOW 4 ADJUSTING SETTING 5 PANEL PARAMETERS 7 OPERATION 11 TROUBLE SHOOTING 13 SERVICE PARTS POLICY 15 PARTS LIST 16 PNEUMATIC FLOW 25 ELECTRIC DIAGRAM...

Страница 11: ...ight 7 5mm Overedge Width 4mm Fabric Thickness 6 5mm Max Air Consumption 35 L min Air Pressure 0 5 Mpa Power Supply Single Phase 1 AC200 240V 50 60Hz Power Consumption 500 W Max Machine Dimensions W 8...

Страница 12: ...Install the Thread Holder onto the Table Please refer to the operation manual of Siruba 747KST INSTALLATION THREADING P2...

Страница 13: ...ounding wires are well connected 3 Check and make sure the power switch is set OFF 4 Power Connection Single Phase Connection Air Connection Plug the air supply The air pressure is preset In case you...

Страница 14: ...loading Right pedal Finishing cloth Left pedal start sewing Sewing Flow Abnormal Cycle Abort Press to STOP Trouble Shooting TRIAL Setting Setting complete Sewing Power ON YES Cycle Complete Mode Sele...

Страница 15: ...ust Cylinder Block to the working position The Cylinder Block must closely move along to Cylinder during the adjustment Tighten Lever when complete 2 Aligning System Apply inner hex driver 2 5 to rele...

Страница 16: ...3 Pulling Roller 1 Apply inner hex driver 2 5 to release screws P6...

Страница 17: ...5 Double Seam Detection 16 N A 17 Safety Switch Indicator 1 10 3 12 2 5 7 8 9 11 4 6 13 14 16 15 17 B Parameter Setting and Adjustment 1 In Trial Mode press P Key to enter Parameter Selection Mode 2 P...

Страница 18: ...0000 9999 1 ms Setting the time to enable the stepping motor after pressing the start switch 12 BB Stretching wheel delay 0000 9999 5 ms Setting the time to enable the stretching wheel solenoid valve...

Страница 19: ...ness 34 FT The initial full output time of presser electromagnet 0 990 250 ms Presser Foot Magnetic Setting DO NOT CHANGE 35 FD Presser Foot Cycle 10 50 25 The motion cycle of the presser foot electro...

Страница 20: ...to running start time 1 20 2 s Set time to start the auto running 67 AO2 Auto running stop time 1 20 2 s Set time to stop the auto running 68 AOS Auto Running ON OFF OFF ON Enable the auto running tes...

Страница 21: ...Supply Setting 0 5Mpa 5kg c 2 To upload the material Insert the rib cuff into the fleece sleeve seam facing outward Align the edges and make sure the seams are overlapped Then load the material onto...

Страница 22: ...3 1 2 P12...

Страница 23: ...is too high cannot detect cross seam to end the operation Adjust the sensor of cross seam system Cross Seam System Cross Seam Sensor Bad Cutting Not enough reserved stitch after ejection Not enough s...

Страница 24: ...control box cools down 2 Reboot the system If the error code still exists please contact us or authorized agents Err 21 Motor Encoder Abnormal 1 Turn off the power 2 Check if the power cable connectio...

Страница 25: ...i...

Страница 26: ...CAUTION Moving parts may cause in jury Operate with safety devices Turn off main switch before threading changing bobbin and needle cleaning etc SIRUBA APP APP Apple Store APP Google Play APP...

Страница 27: ...1 1 2 3 4 2 1 2 3 4 3 1 2 3 4 1 2 3 5 1 2 3 4 6 7 8...

Страница 28: ...1 1 2 3 2 1 2 3 3A 1 2 3B 1 2 30mm 3 4 3C 1 2 3D 1 2 4 1 2 3 4...

Страница 29: ...5 1 2 3 4 5 6 6 1 2 3 7 1 2 3 4 5 6 7 8 8 1 2 10 3 4 5 C 35 C 35 85 5 6 7 8 9...

Страница 30: ...ASM 1 2 OFF...

Страница 31: ......

Страница 32: ...1 2 4 5 7 11 13 15 16 25 26...

Страница 33: ...ASK ASM100 SIRUBA 747KST 5500 SPM Max DC 27 11 2mm 7 5mm 4mm 6 5mm Max 35 L min 0 5 Mpa Single Phase 1 AC200 240V 50 60Hz 500 W Max W 825 D 640 H 1622mm mm Height 20 90mm 225 440mm P 1...

Страница 34: ...747KST P 2...

Страница 35: ...1 AC220V 10 0 5Mpa 5kg cm2 2 3 OFF 4 PE L1 L2 PE P 3...

Страница 36: ...P 4 ON YES NO NO NO YES YES...

Страница 37: ...1 2 2 5 P 5...

Страница 38: ...3 1 2 5 P 6...

Страница 39: ...A 1 2 3 4 5 6 7 LED 8 9 10 11 12 13 14 15 16 17 1 10 3 12 2 5 7 8 9 11 4 6 13 14 16 15 17 B 1 P 2 3 S 4 5 S P 6 7 S 0168 P 7...

Страница 40: ...9999 8 SV 200 6500 9 TMD NOP CUF PAN CUF NOP CUF PAN 10 MRM MA OT A MA MA OT A 11 AA 1 ms 12 BB 1 ms 13 CC 10 ms 14 DD 50 SENSOR 15 EE 15 16 FF 2000 ms 17 GG 1 SENSOR ms 18 HH 80 14 19 IRD Y 240 1200...

Страница 41: ...2 7 82 8 9 10 11 12 82 33 TIN 0 1 2 3 0 3 34 FT 0 990 250 ms 35 FD 10 50 25 36 FPM ON OFF ON 37 FP 1 300 120 30 38 FMM ON OFF ON 38 FMM ON 39 FMS 39 FMS 1 3000 10 ms 40 HT 0 990 100 ms 48 FMD 50 500 5...

Страница 42: ...63LVR AC 63 LVR 64 PV 65 AOT 1 500 240 66 AO1 1 20 2 s 67 AO2 1 20 2 s 68 AOS ON OFF OFF ON OFF OFF 69 UTT 1 1000 Accumulate running time 70 VER SXEX UI 71 GHT ON OFF OFF ON OFF 78 PS Password OFF ON...

Страница 43: ...1 1 AC 220V 10 2 0 5Mpa 5kg c 2 P 11...

Страница 44: ...3 1 2 P 12...

Страница 45: ...B Sensor Sensor Sensor A Sensor 14 18 Err 1 1 2 IGBT 3 Err 4 1 2 3 4 P 13...

Страница 46: ...Err 7 1 2 3 4 5 Err 8 1 2 3 Err 17 1 2 3 Err 20 1 10 2 Err 21 1 2 3 Err 24 1 2 3 Err 60 1 2 3 1 2 P 14...

Страница 47: ...damage to the operator and property In some cases issues such as difficulty of obtaining parts might make it impossible for us to repair or replace malfunctioning items even if the service period has...

Страница 48: ...es Parts Group Subclass Remark Page Date 1 2 3 4 5 E D B C A ASM 0001 A ASM 0047 ASM 0012 A ASM 0019 A ASM 0009 A EBS 1006 ASM 0005 A SM611N 2 ASM 0032C E BQ19 TUA 39ST EC446 1 1 ASK ASM100 ASK ASM100...

Страница 49: ...Group Subclass Remark Page Date 1 2 3 4 5 E D B C A ASM 0011 2 ASM 0054 ASM 0001 WM5000 SM611N WM601 SK934 SM411N 2 WM406N 2 ASM 0002 ASM 0003 ASM 0004 NM610N JA042 2 AC800 ASM 0001 A ASK07 ASK ASM100...

Страница 50: ...008 AC709 ASM 0025 SM313N 8 ASM 0036 AMT 0036 WM110 8 SM313N 4 AMT 0041 SM318N 2 WM301 2 WM110 4 ASM 0041 ASM 0039 ASM 0040 2 ASM 0027 ASM 0037 ASM 0038 ASM 0027 E ASM 0067 WM301 7 UWB 0031 ASM 0062 S...

Страница 51: ...E D B C A SM313N 3 ASM 0009 A ASM 0033 ASM 0010 ASM 0009 SM313N ASM 0014 ASM 0013 ASM 0012 ASM 0018 SM359N 3 ASM 0029 WMA10 2 WMA0A 2 SM916 2 ASM 0016 AC918 SM3101N 4 SM611N 2 JA042 2 ASM 0015 WM601 N...

Страница 52: ...PARTS LIST Series Parts Group Subclass Remark Page Date 1 2 3 4 5 E D B C A ESH004301 ESH004502 ASM 0026 SK438 3 SM411N 4 ASM 0019 1 1 ASM 0019 A P 20 5 9...

Страница 53: ...5 E D B C A SM8105N 2 AMT 0018 AMT 0016 SK8A1 6 KX09 6 SW07 6 NK45 12 WM8000 2 WM811 2 NM814 2 ASM 0057 ASM 0030 KD425 ASP 0210 A ASM 0023 BK322 E ASM 0058 SM4052 13 ABF450 ASL 0043 WM600 2 SM6104N 4...

Страница 54: ...es Parts Group Subclass Remark Page Date 1 2 3 4 5 E D B C A ASM 0032 JA051 4 JA015 2 8 ESV013G07 SK392 2 ESV011107 7 JA062 3 JA023 3 JA022 8 ESV013K07 SM3050 14 6 ESV014107 1 1 ASM 0032C E ASK ASM100...

Страница 55: ...PARTS LIST Series Parts Group Subclass Remark Page Date 1 2 3 4 5 E D B C A NK26 2 AC058 BK324 BK322 BK323 SK266 2 JA021 1 1 BK322 E ASK ASM100 2018 09 20 ASK07 P 23 8 9...

Страница 56: ...P 24 9 9...

Страница 57: ...P 25...

Страница 58: ...P 26...

Страница 59: ......

Страница 60: ...The specification and or appearances of the equipment described in this instruction book parts list are subject to change because of modification which will without previous notice ASK ASM100 OCT 2019...