Page 10
4.2
Switch Definition
It is necessary that the dome ID and communication protocol remain in the default modes when
connecting the MSD622 cameras to other devices. The switches used for configuring these
settings are located on the bottom of the dome camera. These settings are preset to operate the
camera with the IP hardware. Changing the settings may make the camera inoperative using the
IP connection.
Refer to the figure and table below for switch location and definitions.
MSD622 switches
Switch Definition
A Communication
switch
B
ISP connector (for firmware upgrades)
C RJ-45/SFP
connector
D
SD card slot
E Reset
buttons
F 22-pin
connector
Note:
Switch E has two buttons. Only the button closest to the 22-pin connector is used to
restore factory server defaults. The other button is reserved.
To restore factory server defaults
Power up the camera while holding button E. Continue to hold the button for 30 seconds
after powering the camera.
4.3
Communication Switch Configuration
The MSD622's communication switch is specified in the table below. The default settings are
depicted in the figure. You are advised to verify the accuracy of the communication switch
configuration but do not change the default settings, or some functions may not work properly.