SIQENS Ecoport 800
Nominal voltage
24 V DC
48 V DC
Voltage range
20
–
31 V DC
40
–
64 V DC
Backup Power (max.)
800 W
Charging capacity per day (max.)
19.2 kWh
Charging current (max.)
33.3 A
16.7 A
Primary Power
500 W
Charging capacity per day
12 kWh
Charging current
20.8 A
10.4 A
Stack performance (Primary Power)
min. 3,000 operating hours / 500 cycles
Fuel
Methanol
(IMPCA, > 99.85%)
Consumption
0.6 l/kWh*
Power consumption in standby (Sleep
Mode)
< 0.1 W
Electrical efficiency
38%*
Starting time
30 min. (at 20°C)
Noise level (at 7 m)
< 45 dB(A)
Exhaust temperature
< 65°C
Compatible batteries
Lithium-Ion
LiFePO4
Lead acid
Lead gel
AGM
Recommended battery capacity (min.)
2 kWh (net)
84 Ah**
2 kWh (net)
42 Ah**
Dimensions (L x W x H)
770 x 350 x 420 mm
Weight (without packaging)
46 kg
Protection class
IP 20
Starting temperature
- 20°C / + 50°C
Storage temperature
- 20°C / + 50°C
Max. inclination during operation
10°
Recommended altitude
Tested up 2,700 m
Technical changes reserved
For performance-enhancing operation and to reduce methanol consumption, the power output of the
Ecoport in Primary Power Mode can vary depending on the load.
* Depending on ambient conditions
** Dependent on overall energy system configuration and load (e.g. higher capacity
recommended when additional energy sources such as solar are installed).