10. Maintenance work
WARNING!
Before starting any repair or maintenance work, please read the safety information in section 2.F.
„Safety during repair and maintenance”.
ATTENTION!
•
When working with powder, wear individual protection (Protective Gloves,
antistatic shoes, face protection: Protective Glasses, Protective Dust Mask).
•
When working with a PHS device, hearing protection is required.
•
To prevent dust from being inhaled at all times, always wear respiratory
protection (dust mask).
A. CHECKING THE CONDITION OF THE SIEVE AND REMOVING DIRT FROM IT
1. Start working only with the vacuum cleaner switched off.
2. Open the door of the Sifting module
11
and tapping the flexible tube of the sieve
28
so that the powder from the
walls falls on the Vibrating Sieve
30
(image 43).
3. Remove the sieve locking pin and unfasten the clamping ring
29
(image 44)
Image. 43. Tapping the flexible tube
to remove from the powder.
Image. 44. Remove the pin and unfasten
the clamping ring.
4. Lift and attach the sieve Flexible tube with the flange
28
to the magnetic holders of the Sieve flange
27
. Put a
clamping ring on the flange so that it does not fall on the sieve
30
(image 45).
5. Release the drawer locks of the sieve
32
and Metal container
38
.