163
Messages and Error Codes (A611DN)
Service Error Codes
Generally, it is not possible to recover when service error code is displayed, but temporary
errors may disappear when POR the printer.
Service Error Code (3xx)
Error
Description
Action
300
Fuser under
temperature while
printing
Occurs when Fusing temperature is lower than the set
temperature for more than 30 seconds while printing
1.
Check the harness between Fusing and power
unit
2.
If the problem is not solved, replace the Fusing
unit
301
Fuser under
temperature while at
standby
Occurs when Fusing temperature is lower than the set
temperature for more than 30 seconds during stand by
1.
Check the harness between Fusing and power
unit
2.
If the problem is not solved, replace the Fusing
unit
302
Fuser failed to reach
standby temperature
Occurs when Fusing temperature does not reach stand-
by temperature within 90 seconds after POR
1.
Check the harness between Fusing and power
unit
2.
Check the harness between system card and
thermistor
3.
If the problem is not solved, replace the Fusing
unit
303
Fuser over
temperature
Occurs when Fusing temperature goes over 235 degrees
1.
Check the harness between Fusing and power
unit
2.
If the problem is not solved, replace the Fusing
unit
304
Fuser thermistor
failure
Occurs when Fusing temperature does not go over 35
degrees within 10 seconds after POR
1.
Check the harness between Fusing and power
unit
2.
Check the harness between system card and
thermistor
3.
If the problem is not solved, replace the Fusing
unit
305
Fuser under
temperature while
heating
Occurs when fuser temperature drops more than 5
degrees twice in a row while heating.
1.
Check the harness between Fusing and power
unit
2.
If the problem is not solved, replace the Fusing
unit
Содержание A610 Series
Страница 1: ...SERVICE MANUAL A610 A611 SER CS 2014 01 22 CE Confidential...
Страница 26: ...22 Paper Path 1 Output Bin 2 Multipurpose Tray 3 Main Feeder 4 Optional Feed Unit 5 Duplex Unit...
Страница 66: ...62 Forward Rotation Reverse Rotation Fuser Driving Gear Solenoid Activated Fuser Driving Gear...
Страница 72: ...68 2 LCM Connection Part...
Страница 73: ...69 3 Button Input 4 LED Drive...
Страница 74: ...70 5 Backlight Control 6 POWER BUTTON POWER LED...
Страница 94: ...90 2 AC DC Rectification Unit 3 24V Output Unit...
Страница 95: ...91 4 5V Output Unit 5 AC Drive Section 6 Switching Unit...
Страница 96: ...92...
Страница 97: ...93 Circuit Diagram HVPS Input Section 1 PWM Input Section 2 RCC Control Drive Section...
Страница 98: ...94 3 High Voltage Output 4 TX SENSING Unit...
Страница 102: ...98 Be careful not to damage the 7 hooks inside the cover when removing the right cover...
Страница 116: ...112 4 Separate 3 connectors marked by red circles...
Страница 121: ...117 MAIN FAN SUB FAN...
Страница 125: ...121 3 Press left and right hooks and remove the feeding roller A ssy 4 Pickup roller A ssy removed 5 Pickup tire removed...
Страница 135: ...131 7 Remove E ring and bushing to remove feeding roller shaft...
Страница 138: ...134 5 Disassembled Pickup Tire...
Страница 141: ...137 6 Remove the E Ring and bushing and separate the feeding roller shaft...
Страница 145: ...141...
Страница 154: ...150 4 Loosen bolts on both sides and remove the exit frame 5 Undo the ground connecting harness bolt in the fuser frame...
Страница 156: ...152 8 Remove the E ring holding the shaft 9 Remove Accufeed spring Use sharp tool...
Страница 212: ...208 from step 1...
Страница 217: ...213 from step 1...