Swimming pool-water pump protection

Swimming-pump

-----

14

Incorrect capacity DIP switch setting

Capacity DIP

c5

15

Communication error between  indoor and outdoor unit

ODU-IDU Com.

E6

16

Drive communication error

Drive com.

-----

17

High pressure sensor error

HI-pre. sens.

FC

18

Enthalpy-enhancing sensor error

En. senser

F8

19

Low pressure sensor error

LOW-pre. Sens.

dL

20

Heat exchanger-leaving water temperature sensor error

Temp-HELW

F9

21

Auxiliary heater-leaving water temperature sensor error

Temp-AHLW

dH

22

Heat exchanger-entering water temperature sensor error

Temp-HEEW

-----

23

Water tank water temperature sensor 1 error

Tank sens. 1

-----

24

Water tank water temperature sensor 2 error

Tank sens. 2

FE

25

Solar kit-entering water temp sensor

T-SL water out

-----

26

Solar kit-leaving water temp sensor

T-SL water in

FH

27

Solar kit- temp sensor

T-solar battery

FF

28

Swimming pool-entering water temp sensor

T-Swimming in

-----

29

Swimming pool-leaving water temp sensor

T-Swimming out

-----

30

Swimming pool-water temp sensor

T-Swimming

-----

31

Remote room sensor 1

T-Remote Air1

F3

32

Remote room sensor 2

T-Remote Air2

-----

33

Heat pump-water flow switch

HP-Water SW

Ec

34

Solar kit-water flow switch

SL-Water SW

F2

35

Swimming pool-water flow switch

SW-Water SW

F1

36

Welding protection of the auxiliary heater 1

Auxi. heater 1

EH

37

Welding protection of the auxiliary heater 2

Auxi. heater 2

EH

38

Welding protection of the water tank heater

Auxi. -WTH

EH

39

Under-voltage DC bus or voltage drop error

DC under-vol.

PL

40

Over-voltage DC bus

DC over-vol.

PH

41

AC current protection (input side)

AC curr. pro.

PA

42

IPM defective

IPM defective

H5

43

PFC defective

FPC defective

Hc

44

Start failure

Start failure

Lc

45

Phase loss

Phase loss

LD

46

Communication error to the drive with Main board 

drive-main com.

P6

47

Drive module resetting

Driver reset

P0

48

Compressor over-current

Com. over-cur.

P5

49

Overspeed

Overspeed

LF

50

Sensing circuit error or current sensor error

Current sen.

Pc

51

Desynchronizing

Desynchronize

H7

52

Compressor stalling

Comp. stalling

LE

53

Radiator or IPM or PFC module overtemperature

Overtemp.-mod.

P8

54

Radiator or IPM or PFC module temperature sensor error

T-mod. sensor

P7

55

Charging circuit error

Charge circuit

Pu

Содержание SMH-100IRA? SMH-140IRA

Страница 1: ...AIR TO WATER HEAT PUMPS SMH 100IRA SMH 140IRA MONOBLOCK INVERTER...

Страница 2: ...Original instructions...

Страница 3: ...nual are only for reference 2 In order to make the product better we will continuously conduct improvement and innovation We have the right to make necessary revision to the product from time to time...

Страница 4: ...View 1 1 1 Keys Indicating LEDs 1 1 2 Standby Page and Homepage 2 2 Operation Instructions 3 2 1 On Off 3 2 2 Function Setting 4 2 3 Parameter Setting Parameter Set 20 2 4 View 23 2 5 General Setting...

Страница 5: ...n when some fault occurs 4 Left key It is intended to move the cursor left 5 Up key It is intended to modify the setting state or value of the selected parameter 6 Menu key It is intended to call out...

Страница 6: ...is any error 4 T water out It indicates the actual leaving water temperature 5 T outdoor It indicates the actual outdoor environment temperature 6 Key lock It indicates if the key lock is activated o...

Страница 7: ...vated it will be deactivated by pressing the ON OFF key and then press the ON OFF key again to start the unit e ON OFF operation will be memorized by setting Memory to be On at the GEN setting page Th...

Страница 8: ...The function key no 3 or no 4 can be used for switch pages After the setting is finished by pressing the Menu key the control will back to the homepage or by pressing the Return key the control will...

Страница 9: ...e changed by the user When the Floor config is set to Without this setting can be changed freely 5 Cool hot water Cool hot water Cool Hot water Cool When the water tank is unavailable this function wi...

Страница 10: ...cation error and the ON command can be performed only when 40 seconds have been expired When it is set to Air hot water hot water can be performed even though the thermostat is off 20 Assistant heater...

Страница 11: ...ation Instructions At the equipment OFF state access to the FUNCTION page and then move through the Left Right key the cursor to the Mode whose characters will be reversed then press the Up Down key t...

Страница 12: ...High 35 C 95 F Normal Lower limit water out temperature at the weather dependent mode for heating Lower WT Heat 40 C 104 F High 25 C 77 F Normal b This setting will be memorized upon power failure 2...

Страница 13: ...Save a pop up window will pop up to remind if you are determined to save this setting If so press the OK key If not press the Cancel key to not save this setting 4 When the setting is saved the contr...

Страница 14: ...anitize the water tank by raising the water temperature to 70 C under which the legionella will die immediately When this function is activated the sanitation data and start time is configurable Opera...

Страница 15: ...ons 1 At the homepage by pressing the Function key access to the FUNCTION page and then locate where Weekly timer is by switching pages after that press OK key to go to the WEEKLY TIMER setting page 2...

Страница 16: ...T water out will be the default value 35 c When Weekly timer has been set successfully water heating solar heater or water tank heater is available and water temperature set point is higher than 50 at...

Страница 17: ...C 1 C Heat Room temperature for heating RT heat 18 30 C 20 C 1 C 2 2 13 Clock Timer This function will make the unit run with certain modes in certain periods within a day based on the user s actual d...

Страница 18: ...Instructions 1 At the homepage by pressing the Function key access to the FUNCTION page and then locate where Temp timer is after that press OK key to go to the TEMP TIMER setting page 2 At the TEMP T...

Страница 19: ...ress OK to confirm the configuration or press Cancel to cancel this configuration 4 After saving the configuration this page will automatically back to the FUNCTION page with the cursor stayed at Sola...

Страница 20: ...nly when the unit is OFF When it is intended to activate this function with the unit being ON a dialog box will pop up warning Please turn off the system first b When this function has been activated...

Страница 21: ...er and Temp timer also cannot be activated or will be deactivated if being activated d At the Emergency mode commands from the Thermostat is ineffective e At the Emergency mode only one running mode b...

Страница 22: ...minate water heating when the thermostat is turned off g Under the Without mode the unit will run based on the mode set by the controller h The status of the thermostat can be changed only when the un...

Страница 23: ...will be memorized upon power failure 2 2 26 Water Tank It can be configured to be With or Without based on the actual condition Operation Instructions Go to the FUNCTION page and locate Water tank th...

Страница 24: ...or Off Notes a It will not be memorized upon power failure b It can be set only when the unit is turned off 2 2 32 Address It is used to identify the unit in use in the central control system Operati...

Страница 25: ...o press the OK key if not press the Cancel key to not save this setting Notes For those parameter which default value vary by different condition the value will set to default when the condition chang...

Страница 26: ...e Weather depedent mode changes it will back to the default value 13 Lower limit room temperature at the Weather dependent Mode for heating Lower RT Heat 18 21 C 64 70 F 18 C 68 F Once setting of the...

Страница 27: ...mit water out temperature at the weather dependent mode for cooling Lower WT Cool 7 14 C Without underfloor coil 18 21 C With underfloor coil 45 57 F Without underfloor coil 64 70 F With underfloor co...

Страница 28: ...h component HP pump SL pump Swimming pump Viewable Components Full Name Displayed Name Status Compressor running state Compressor On Off Fan 1 running state Fan 1 On Off Fan 2 running state Fan 2 On O...

Страница 29: ...ction temperature discharge temperature water in temperature water out temperature etc Operation Instructions 1 At the VIEW page select Parameter and then press the OK key to go to the Para View page...

Страница 30: ...rors follow the same way b If the total no of errors exceed six other errors should be viewed by switching pages through Last and Next c Any one among IDU auxiliary heater 1 error IDU auxiliary heater...

Страница 31: ...imming 31 Remote room sensor 1 T Remote Air1 F3 32 Remote room sensor 2 T Remote Air2 33 Heat pump water flow switch HP Water SW Ec 34 Solar kit water flow switch SL Water SW F2 35 Swimming pool water...

Страница 32: ...ng Solarsuperheat F6 2 4 4 Version View VERSION At the version view page the user is enabled to see the version of the program and the protocol Operation Instructions 1 At the VIEW page select Version...

Страница 33: ...for 1 minute and will lights on where there is any key operation 2 5 1 Time Date Operation Instructions 1 At the homepage by pressing GEN access to the GENERAL SET page Then select Time Date at this...

Страница 34: ...y key operation will become ineffective Operation Instructions At the homepage by pressing the up and down keys simultaneously for 5 seconds it is able to activate or deactivate this function When it...

Страница 35: ......

Страница 36: ...ces you are making an important contribution to the protection of our environment Please ask your local council where your nearest disposal station is located In case of quality problem or other pleas...

Отзывы: