20
Go to the
FUNCTION
page and locate “
Floor config
”, then, configure it through the Up/Down key
,
“
With
” or “
Without
”.
[Notes]
(a) It will be memorized upon power failure.
(b) When it is set to be “with”, "Normal temp" is defaulted and unconfiguralbe; when it is set to "Without", "High
temp" is defaulated and hot water temperature can be set freely.
(c) “Floor config” can be changed only when the unit is turned off.
2.2.30 Remote Sensor
It can be configured to be “
With
” or “
Without
” based on the actual condition.
[Operation Instructions]
Go to the
FUNCTION
page and locate “
Remote sensor
”, then, configure it through the Up/Down key
, “
With
” or “
Without
”.
[Notes]
(a) It will be memorized upon power failure.
(b) “
T-room ctrl
” can be selected only when the
Remote Sensor
is set to “
With
”.
2.2.31 Air removal
This function is intended to expel air inside the water system with only the water pump in operation when
installation of the unit is finished.
[Operation Instructions]
Go to the
FUNCTION
page and locate “
Air removal
”, then, configure it through the Up/Down key
,
“
On
” or “
Off
”.
[Notes]
(a) It will not be memorized upon power failure.
(b) It can be set only when the unit is turned off.
2.2.32 Address
It is used to identify the unit in use in the central control system.
[Operation Instructions]
Go to the
FUNCTION
page and locate “
Address
”, then, configure it through the Up/Down key
to
set the address.
[Notes]
(a) It indicates the address of the control and is intended for the group control.
(b) It will not be memorized upon power failure.
(c) The address range is [1,125] and [127,253]
(d) The default address is 1 for the initial use.
2.2.33 Gate-Controller(Gate-Ctrl.)
It can be configured to be “
On
” or “
Off
” based on the actual condition.
[Operation Instructions]
Go to the
FUNCTION
page and locate “
Gate-Controller
”, then, configure it through the Up/Down key
, “
On
” or “
Off
”.
[Notes]
(a) When it is activated, the control will check the card is inserted or not. If inserted, the control will run
normally; if not, the control will turn off the unit and back to the homepage. In this case, any key operation
is ineffective (except for the combined key operation), or a dialogue box will pop up, warning"
Keycard
uninserted!
".
(b) It will not be memorized upon power failure.
2.3 Parameter Setting (Parameter Set)
2.3.1 User Parameter Setting