| 19
Installation |
V5035 Operator and Installation Manual
Connecting to MX5035 Junction Box
Use the following guidelines to connect the Pilot Plug to the V5035
Junction box. Refer to External Connectors (Junction Box) page 21.
To transponder main unit
Pilot plug
PILOT_IN A connects to Rx A (Black)
PILOT_IN B connects to Rx B (Green)
PILOT_IN GND connects to Shield
PILOT_OUT A connects to Tx A (Red)
PILOT_OUT B connects to Tx B (White)
PILOT_OUT GND connects to Shield
Note:
Shield can connect to either
PILOT_IN GND or PILOT_OUT GND.