112 |
Appendix B |
V5035 Operator and Installation Manual
Appendix B
Monitoring of System Functions and Integrity
In case a failure is detected in one or more of the following func-
tions or data, an alarm will be triggered and displayed on the menu-
tree under Alarm List, and the system (transponder) will react as
described in the following table.
Alarm-s description text
Alarm ID Reaction of the system (transponder)
AIS: Tx malfunction
001
Stop transmission
AIS: Antenna VSWR exceeds limit
002
Continue operation
AIS: Rx channel 1 malfunction
003
Stop transmission on affected channel
AIS: Rx channel 2 malfunction
004
Stop transmission on affected channel
AIS: Rx channel 70 malfunction
005
Continue operation
AIS: general failure
006
Stop transmission
AIS: UTC sync invalid
007
Continue operation using indirect or sema-
phore synchronisation
AIS: MKD connection lost
008
Continue operation
AIS: internal / external GNSS posi-
tion mismatch
009
Continue operation
AIS: NavStatus incorrect
010
Continue operation
Heading sensor offset
011
Continue operation
AIS: active AIS SART
014
Continue operation
AIS: external EPFS lost
025
Continue operation
AIS: no sensor position in use
026
Continue operation
AIS: no valid SOG information
029
Continue operation using default data
AIS: no valid COG information
030
Continue operation using default data
AIS: Heading lost/invalid
032
Continue operation using default data
AIS: no valid ROT information
035
Continue operation using default data
Antenna VSWR Exceeds Limit
There is a built-in RF output power detector, which is used to moni-
tor the VSWR of VHF antenna port. If the antenna VSWR exceeds
limit, an alarm will be reported while the unit operates continuously.
The system will output an ALR 002 at related PI port.
Содержание V5035
Страница 1: ...ENGLISH V5035 Operator and Installation Manual pro simrad yachting com...
Страница 2: ......
Страница 77: ...77 Mechanicaldimensions V5035OperatorandInstallationManual Back size mm Bottom size mm...
Страница 78: ...78 Mechanical dimensions V5035 Operator and Installation Manual Junction box Extension cable...
Страница 79: ...79 Mechanicaldimensions V5035OperatorandInstallationManual Mounting template not to scale VHF antenna...
Страница 80: ...80 Mechanical dimensions V5035 Operator and Installation Manual GPS antenna...
Страница 81: ...81 Mechanicaldimensions V5035OperatorandInstallationManual Pilot plug...
Страница 118: ...988 10838 001...