Ż
GOTO
t SimNet diagnostic
PLOT
Ź
Example:
CX44/54
Alarm:
Output (pin 1,2): ON
Alarm stand-by level: LOW
Pos-status:
Output (pin 4,6): ON
Pos-status stand-by level: HIGH
Log:
Output (pin 5,6): ON
MOB-input:
(pin 3,6)
Long press (5 sec.): EXTERNAL MOB
Short press: OFF
MENU
Exit Accept
ENT
Ʃ
Ʃ
Alarm
Setup menu
Chapter 9-21
MOB-input
•
Press the external switch for more than 5 seconds to activate the
MOB function (fixed setting), and press the [ENT] key to start MOB
navigation.
•
Short press on the external switch (less than 5 seconds) will shift
page or plot ship’s position. Use the +/- keys to toggle between OFF,
SHIFT PAGE and PLOT SHIP’s POS:
SHIFT PAGE - short press on the external switch will shift to next
page stored under the PAGE key.
PLOT SHIP’s POS - short press on the external switch will plot and
save the actual position, which will be registered in the WP list.