'O TO AND CHANGE COLOR SETTINGS
#ONFIRM NEW SETUP
,OAD DISPLAY
The
DUAL SPEED DISPLAY
will show water speed from
external log sensor (via
ECHO
port) when ’Log
speed sensor’ is set ON.
When set OFF (and
NMEA sentence VHW set
ON) the readout will
show water speed from
external water speed sen-
sor (via
NMEA
port).
With ’Log speed sensor’
OFF and NMEA sentence
VHW OFF, the readout
will show current date.
Calibrate log speed readout by increasing/decreasing the
number of pulses per nautical mile - see also Appendix A.
'O TO THE FUNCTION YOU WISH TO CHANGE
3ELECT NEW VALUES
#ONFIRM ENTRY
The
SPEED ALARM
can be set to maximum and/or a mini-
mum cruising speed. This may be handy for trawl fishing,
entering into harbours with speed limits, etc.
3ETUP FOR SPEED ALARM UNITS
AND LANGUAGE
KEYS TO PRESS
Setup for speed:
LOG speed sensor:
ON
LOG speed calibration:
019000 PULSES/nm
Speed alarm maximum
(SOG)
: 00.0kn
OFF
Speed alarm minimum
(SOG)
: 00.0kn
OFF
Setup for units:
Depth/altitude in:
METRES
Distance in:
NAUTICAL MILES
Speed in:
KNOTS
Temperature in:
DEGREE CELCIUS
Software version:
CE32 3.08 MKII
WIN change interval: 5 sec.
MANUAL
Display text in:
ENGLISH GB
+/-
ENT
6,1
MENU
+/-
ENT
0-9
#% -+)) 3ETUP
#HAPTER
81
Содержание ce32 mkii
Страница 84: ... HAPTER 3ETUP 84 ...