background image

 
 

 
 

 

4010-9806

Class A

Module

4010-9806

Class A

Module

TB4

TB3

P2

TB1

NAC 1

NAC 2

NAC 3

NAC 4

SH

LD

SH

LD

EXT N2

IDNet

A +

A -

B +

B -

NC

C

NO

AUX2

AUX1

BATTERY

AUX

POWER

NC

C

NO

4010-9813

or

4010-9823

Expansion Power Supply

4010-9809

or -9829

City Module

or

4010 -9803 

Relay Module

4010-9825

24 VDC Power 

Distribution

Block

TB5

TB6

TB7

TB8

SUPV

ACK

SYSTEM

SUPERVISORY

ALARM

ACK

FIRE

ALARM

TROUBLE

ACK

SYSTEM

TROUBLE

ALARM

SILENCE

ALARM

SILENCED

SYSTEM

RESET

AC

POWER

MENU

FUNCTION

ENTER

DISABLE
ENABLE

EXIT

CLEAR

PREVIOUS

NEXT

Expansion

Slots 1 & 2

 

 

 

 

Tyco Fire Protection Products • Westminster, MA • 01441-0001 • USA

 

S4010-0001-14  6/2014

 

 

www.simplex-fire.com

 

© 2014 Tyco Fire Protection Products. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice. 

 

  Typical conduit entry area

(cut holes as required)

Battery Area

No conduit entry or wiring in this area

18" (457 mm)

21"

(533 mm)

14-1/2" (368 mm)

WATERFLOW-

LEFT WING

GROUND FAULT

WATERFLOW-

RIGHT WING

SUPV

ACK

SYSTEM

SUPERVISORY

ALARM

ACK

FIRE

ALARM

 TROUBLE

ACK

SYSTEM

TROUBLE

ALARM

SILENCE

ALARM

SILENCED

SYSTEM

RESET

AC

POWER

MENU

FUNCTION

ENTER

DISABLE
ENABLE

EXIT

CLEAR

PREVIOUS

NEXT

TB4

TB3

P2

TB1

TB5

TB6

TB7

TB8

Shaded area is for non-power limited wiring

Knockout screw/nail holes
(for semi-flush mount)

Wall thickness guides for
5/8" (16 mm) wall board)

Wall thickness guides for
1/2" (13 mm) wall board

Annunciator Door,

1-23/32" (44 mm) thick

7-3/32"

(180 mm)

5-1/2"

(140 mm)

1-19/32"
(40 mm)

Door and exposed

cabinet dimension

for semi-flush mount

2-15/32" (63 mm)

Wall board position reference

for  semi-flush mount

Internal straps are
provided for wiring
management
(2 each side)

Standard Door,

5/8" (16 mm) thick

6-1/4"

(159 mm)

3/4"

(19 mm)

Standard
door profile

Annunciator
door profile

 

 

TYCO, SIMPLEX, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm and 
Signaling Code are registered trademarks of the National Fire Protection Association (NFPA).

 4010 Module Layout Reference 

 Mounting Information 

Содержание TrueAlarm

Страница 1: ...with standard door Description TrueAlarm fire alarm control panels have the ability to provide location accuracy for monitoring and control When equipped with TrueAlarm analog sensing for smoke and he...

Страница 2: ...recognizable audible notification signal audible WALKTEST operation 2 S4010 0001 14 6 2014 SUPV ACK SYSTEM SUPERVISORY ALARM ACK FIRE ALARM TROUBLE ACK SYSTEM TROUBLE ALARM SILENCE ALARM SILENCED SYS...

Страница 3: ...ent levels of smoke obscuration in percent or for specific heat detection levels In order to evaluate whether the sensitivity should be revised the peak value is stored in memory and can be easily rea...

Страница 4: ...ENCED SYSTEM RES ET AC POWER Local maintenance computer One connection type per 4010 selected by module choice max wiring distance is 300 ft 91 m 9600 baud RS 232 Connection Options refer to module s...

Страница 5: ...ork Interface Modular Media Available for wired connections or fiber optic Require separate media modules May be both wired both fiber optic or one of each Optional Expansion Slot Modules Cont d Netwo...

Страница 6: ...liances rated 2 A for Regulated 24 DC appliance power 4010 9823 240 VAC input Optional Features select as indicated 4010 9825 24 VDC Expansion Power Distribution Module provides two additional termina...

Страница 7: ...each maximum up to 33 synchronized strobes maximum per NAC Current Ratings for Optional Modules and Remote LCD Annunciator Model Module Supervisory Current Alarm Current 4010 9810 DACT Common Event Re...

Страница 8: ...1 2 368 mm WATERFLOW LEFT WING GROUND FAULT WATERFLOW RIGHT WING SUPV ACK SYSTEM SUPER VISORY ALARM ACK FIR E ALARM TROU BLE ACK SYSTEM TROUBLE ALARM SILENCE ALARM SILENC ED SYSTEM RESET AC POWER MENU...