background image

 

 

 5 

S4100-0035-2 

 

5/02

Audio Riser Modules 

Model 

Description 

Size 

Supv. 

Alarm 

4100-0621 

Dual Channel 

Analog

 Audio Riser Module, accepts two separate audio signals from 

host control panel; mounts in Block B, is controlled by Transponder Interface Module 

1 Block 

0 mA 

0 mA 

4100-0622 

3-8 Channel 

Digital

 Audio Riser Module; similar to analog module, except receives 

and decodes a digital input signal with up to eight audio channels 

1 Block 

50 mA  50 mA 

Analog

 Emergency Voice/Alarm Communications Equipment*

 

Model 

Description 

Details 

4100-1212 

Flex-50, 50 W Amplifier, 25 VRMS output 

4100-1213 

Flex-50, 50 W Amplifier, 70.7 VRMS output 

Includes three on-board Class B audio NACs; power 
is supplied from an XPS, RPS, or SPS 

100 W 

Analog

 Amplifiers with Power Supply 

Output 

(VRMS) 

Model 

25 

70.7 

Description 

Power Supply 

Input/Listing 

Details 

4100-1214 

 

 

4100-1215 

 

 

120 VAC, 60 Hz 

UL 

Includes six Class B audio NACs 

4100-1216 

 

 

4100-1217 

 

 

120 VAC, 60 Hz,  
for Canada 

ULC 

Includes six Class B audio NACs and low 
battery dropout circuit 

4100-1218 

 

 

4100-1219 

 

 

100 W Amplifier  

with power supply 

220/230/240 VAC, 
50/60 Hz 

UL 

Includes six Class B audio NACs 

4100-1220 

 

 

4100-1221 

 

 

120 VAC, 60 Hz 

UL 

Includes six Class B audio NACs 

4100-1222 

 

 

4100-1223 

 

 

120 VAC, 60 Hz,  
for Canada 

ULC 

Includes six Class B audio NACs and low 
battery dropout circuit 

4100-1224 

 

 

4100-1225 

 

 

Backup 100 W 

Amplifier with  

power supply 

220/230/240 VAC, 
50/60 Hz 

UL 

Includes six Class B audio NACs 

Digital

 Emergency Voice/Alarm Communications Equipment*

 

Model 

Description 

Details 

4100-1226 

Flex-50, 50 W Amplifier, 25 VRMS output 

4100-1227 

Flex-50, 50 W Amplifier, 70.7 VRMS output 

Includes three on-board Class B audio NACs; power 
is supplied from an XPS, RPS, or SPS 

100 W 

Digital

 Amplifiers with Power Supply 

Output 

(VRMS) 

Model 

25 

70.7 

Description 

Power Supply 

Input/Listing 

Details 

4100-1228 

 

 

4100-1229 

 

 

100 W  

120 VAC, 60 Hz 

UL 

Includes six Class B audio NACs 

4100-1230 

 

 

95 W 

4100-1231 

 

 

100 W  

120 VAC, 60 Hz,  
for Canada 

ULC 

Includes six Class B audio NACs and low 
battery dropout circuit 

4100-1232 

 

 

4100-1233 

 

 

100 W  

Amplifier  

with power 

supply 

220/230/240 VAC, 
50/60 Hz 

UL 

Includes six Class B audio NACs 

4100-1234 

 

 

4100-1235 

 

 

100 W  

120 VAC, 60 Hz 

UL 

Includes six Class B audio NACs 

4100-1236 

 

 

95 W 

4100-1237 

 

 

100 W  

120 VAC, 60 Hz,  
for Canada 

ULC 

Includes six Class B audio NACs and low 
battery dropout circuit 

4100-1238 

 

 

4100-1239 

 

 

100 W  

Backup 

Amplifier  

with power 

supply 

220/230/240 VAC, 
50/60 Hz 

UL 

Includes six Class B audio NACs 

Options for use with either Analog or Digital Amplifiers 

Model 

Description

 

Details and Mounting Reference 

4100-1245 

Flex-50 Expansion NAC Module 

Provides three additional Class B audio NACS; 
mounts on Flex-50 assembly 

4100-1246 

Flex-50 Class A Adapter Module 

Choose one per 

amplifier 

Converts three on-board NACs to Class A operation; 
mounts on Flex-50 assembly 

4100-1248 

100 W Amplifier Expansion NAC 

Module 

Provides six additional Class B audio NACs; mounts 

on 100 W amplifier assembly 

4100-1249 

100 W Class A Adapter Module 

Choose one per 

amplifier 

Converts six on-board NACs to Class A operation; 

mounts on 100 W amplifier assembly 

*Refer to document S4100-0034 for additional audio information.

Continued on next page

 MINIPLEX Transponder Product Selection

 (Continued)

Содержание SafeLINC 4100U

Страница 1: ...hingindicator Repeatoperationuntilallev ent s areacknow ledged Local tonewills ilenc e A B C A C Po wer D E F G H I J K L MN O P Q R S P 0 S T U V WX Y Z A LARMS Fi reAlarm P rio rity2Alarm S YST EM...

Страница 2: ...ode operation TrueAlarm device alarm LEDs will not operate Local Mode Control Operation Continued Notification Operation Fire alarm conditions reported against a fire alarm point type within a transpo...

Страница 3: ...ignals Syste m indicato r fla sh in g To ne On PressAlarmSile nce How to Reset System PressSys temRese t PressAcktosilen ceton e device ZONE 1 SIG 2 A UX 3 F B 4 IO 5 ID Net 6 P 7 A 8 L 9 N E T ADD R...

Страница 4: ...r supply charger with 250 point IDNet channel 3 Class A B NACs and expansion slot for City Circuit or Alarm Relay option Canadian model has low battery cutout 4 Blocks 175 mA 225 mA 4100 5125 120 VAC...

Страница 5: ...4100 1226 Flex 50 50 W Amplifier 25 VRMS output 4100 1227 Flex 50 50 W Amplifier 70 7 VRMS output Includes three on board Class B audio NACs power is supplied from an XPS RPS or SPS 100 W Digital Amp...

Страница 6: ...AC VDC 1 Slot 15 mA 75 mA 4100 3202 Four DPDT relays 10 A 250 VAC 2 Slots 15 mA 175 mA 4100 3203 Eight SPDT relays 3 A 30 VAC VDC These modules are nonpower limited and wiring must be routed away from...

Страница 7: ...5 4 mm into box For semi flush mounting use a 1 1 2 deep 38 mm 3 gang box Expansion Bay Module Loading Reference Description Mounting Transponder Interface Modules Block A Audio Riser Modules Block B...

Страница 8: ...6 stud Knockout screw nail holes for semi flush mounting Stud alignment markers each side Wall board reference for semi flush mounting 6 stud Optional semi flush trim kit reference Front view box outl...