5.4.4 Kaba Benzing, Siemens, Gantner LEGIC, Primion and ISGUS interface
External access control or time-and-
attendance system
Pull-up resistors
5.5 Notes on SREL2 connection
SREL2.G2 with three card interfaces
It is possible to operate the SREL2 with a total of 3 card interfaces at the
same time (1 x internal and 2 x external). The dip switch must be set to 1
(ON) on the internal card interface for such operation.
External trigger for SREL2.G2
The SREL2 is triggered if a current of +3 to +24 Volt (DC) is added to F1 as
a pulse. This configuration can be used to implement the OMRON function,
for example.
External LED or buzzer to SREL2.G2
An external LED or buzzer can be connected to the F3 and PLUS (+)
connections. The voltage at F3 and PLUS is the same as the supply
voltage. If necessary, the voltage must thus be reduced by a suitable series
resistor.
SREL1+2
(Manual)
5. Connections
23 / 38