27

TRANSPORT AND HANDLING

Machine Identification

Always quote the machine serial number
in all communications to the manufacturer,
Nuova Simonelli.

The machine is transported on pallets
which also contain other machines - all
boxed and secured to the pallet with sup-
ports.
Prior to carrying out any transport or
handling operation, the operator must:
- put on work gloves and protective
f o o t w e a r, as well as a set of overalls
which must be elasticated at the wrists
and ankles.
The pallet must be transported using a
suitable means for lifting (e.g., forklift).

CAUTION: RISK OF IMPACT

OR CRASHING.
During all handling operations, the opera-
tor must ensure that there are no persons,
objects or property in the handling area.
The pallet must be slowly raised to a hei-
ght of 30 cm and moved to the loading
area. After first ensuring that there are no
persons, objects or property, loading ope-
rations can be carried out.
Upon arrival at the destination and after
ensuring that there are no persons,
objects or property in the unloading area,
the proper lifting equipment (e.g. forklift)
shoud be used to lower the pallet to the
ground and then to move it (at approx. 30
cm from ground level), to the storage
area. 

CAUTION: RISK OF IMPACT

OR CRASHING.
Before carrying out the following opera-
tion, the load must be checked to ensure
that it is in the correct position and that,

when the supports are cut, it will not fall.
The operator, who must first put on work
gloves and protective footwear, will pro-
ceed to cut the supports and to storing the
product. To carry out this operation, the
technical characteristics of the product
must be consulted in order to know the
weight of the machine and to store it
accordingly.

CAUTION: RISK OF POLLUTION.

Once the machine has been removed
from the pallet or container, these latter
items must not be disposed of in the envi-
ronment, due to the risks of pollution.

Содержание CUP WARMER

Страница 1: ...who must ensure that the electric power of the system is sufficient to absorb the maximum power input stated on the plate In particular that the size of the wiring cables is sufficient to absorb powe...

Страница 2: ...pliance supply cord If the cord is dama ged switch off the appliance and have a qualified technician change the cord If no longer using the appliance we recommend making it inoperative after removing...

Страница 3: ...ctured in compliance with the EEC directives 89 392 89 336 73 23 89 109 and subsequent modifications With best wishes Nuova Simonelli s r l TECHNICAL CHARACTERISTICS SERIE SERIES MASTER COFFEE CUP WAR...

Страница 4: ...e no persons objects or property loading ope rations can be carried out Upon arrival at the destination and after ensuring that there are no persons objects or property in the unloading area the prope...

Страница 5: ...y cannot be held responsi ble for damage to things or injury to per sons caused by failure to comply with the safety instructions and installation and maintenance instructions contained in this handbo...

Страница 6: ...rder to finish filling the boiler Once the filling operation has been conclu ded the electric resistance of the machine unit and boiler will start up The time requi red for the machine to reach workin...

Страница 7: ...r again Freezer s temperature adjust ment Master Cappuccino version To reach the adjustment s thermostat remo ve the drip tray and the container Turn the grip clockwise to lower the temperature anti c...

Страница 8: ...the programmed amount the new number of cups to be delivered is stored in the machine s memory Press one of the flashing keys NOTE To interrupt the programmed cycle press the Continuous Delivery key a...

Страница 9: ...ress twice the arrow key to return to theMACHINE READYsetting NOTE When the words D R AWER FULL appear on the display it means that the drawer has reached the full limit for coffee grounds Therefore i...

Страница 10: ...d the discharged tablets of coff e e grounds standard internal container or external container In the first case stan dard internal container it is also possible to programme the maximum number of gro...

Страница 11: ...e arrow keys to change the number of coffee grounds min 20 max 40 and press ENTER to confirm this selection When choosing the FREE DISCHARGE function grounds fixed at 200 press ENTER to confirm To exi...

Страница 12: ...al stop control has been used before the programmed dose has been effected DECAF SELECTED Decaffeinated coffee delivery selected PROG CONTINUE Continues program in function PROGRAM DOSES Delivery dose...

Страница 13: ...heck to see that the module is level and if necessary level it Ensure that your hands are dry and then plug in the module Turn the On Off switch to the On position The machine is now working Leave the...

Страница 14: ...its wash cycle Repeat the washing operation this time without inserting the detergent tablet in order to eliminate any detergent resi dues completely The Master Cappuccino Version is equipped to wash...

Страница 15: ...12 replace the plug and turn just lever C to the left Fig 11 C letting water drain out of pipe F until it is no longer salty about 1 2 hour turn lever D to the left Fig 11 D Installation and regulatio...

Страница 16: ...an Note It is advisable to use full fat milk and in case whenever the type of milk is changed it will be necessary to re set Cleaning Before proceeding to disassem bly and cleaning we remind you to se...

Отзывы: