![Simoco SDB680 Скачать руководство пользователя страница 44](http://html1.mh-extra.com/html/simoco/sdb680/sdb680_installation-manual_1275637044.webp)
7.2. SDB680 PREPARATION
WARNING
RF RADIATION. A RF RADIATION HAZARD EXISTS IN THIS EQUIPMENT.
TO AVOID RF INJURY, DO NOT TOUCH THE ANTENNA WHEN THE
TRANSMITTER IS IN USE. DO NOT OPERATE TRANSMITTER WITH
ANTENNA DISCONNECTED. REFER TO EU DIRECTIVE 2004/40/EC DATED
29 APRIL 2004.
1. Ensure that the SDB680 base stations are securely fitted into the rack and that
the power and antenna cables are connected on the rear panel.
2. On the SDB680 rear panel, connect the Tx antenna socket to a suitable dummy
load (for the 50 W base a minimum 60 Watt load can be used provided that it is
suitable for use).
3. Connect an Ethernet switch cable to the Ethernet socket.
4. Switch on the power for the system and, in turn, power up each SDB680 base
station.
7.3. SDMT INSTALLATION AND PREPARATION
1. Refer to the SDMT User Manual [2] and carry out the following:
2. Install the SDMT software in accordance with Todo//Section 1.2 – Software
Installation.
3. Prepare the SDMT software for use in accordance with Todo//Section 2.2 –
SDMT Preparation.
4. Create or establish a connection to a suitable Microsoft SQL Server database in
accordance with Todo//Section 2.2.3 – Database Connection.
7.4. INSTALLING THE SIMOCO IP CONFIGURATION SERVER
1. Refer to the Simoco IP Configuration Tool User Manual [3] and install the
Simoco IP Configuration Server software in accordance with Todo//Section 1.3 –
Software Installation.
2. After installing the Simoco IP Configuration Tool software, ensure that the PC
on which the software is installed is connected to the Ethernet switch via a CAT
5 Ethernet cable.
7.5. 4.5 IP ADDRESS CONFIGURATION
1. On the PC, start the Simoco IP Configuration Tool.
2. If the PC has more than one IP address or Network Connection, when the IP
Configuration Tool is started, the Interface Selection screen will be displayed
see Figure 11
Doc Number:
TNM-I-E-0046 ISSUE 1.2
Page
44