User manual for - TIMER SLC-94
7.2.2.
„ StArt
” parameter
This parameter defines the method of starting the counting (apply to configuration of
{
START }
input).
“
Lo-Hi
”, “
Hi-Lo
”- selection of edge starting the measurement:
”
Lo-Hi
” - rising edge (from low to high state),
“
Hi-Lo
” - falling edge (from high to low state),
“
Lo
”, “
Hi
” - selection of level starting the measurement:
”
Lo
” - low, “
Hi
“ - high. After selection one of these options
{
STOP }
input
and [
^
] [
v
] buttons are inactive, there is no parameter “
StoP
” in the
menu, and it is impossible to start / stop counting via RS-485 interface.
Examples are shown in paragraph 8 on page 25.
7.2.3.
„
StoP
” parameter
This parameter defines the method of stopping the measurement (apply to configuration
of
{
STOP }
input).
Possible values:
“
Lo-Hi
”
- rising edge (from low to high state) stops counting,
“
Hi-Lo
”
- falling edge (from high to low state)stops counting.
Examples are shown in paragraph 8 on page 25.
7.2.4.
“rESEt”
parameter
This parameter defines the method of clearing the counter (apply to configuration of
{
RESET }
input).
Possible values:
”
Lo-Hi
”, “
Hi-Lo
” - selection of edge :
”
Lo-Hi
” - rising edge (from low to high state) ,
“
Hi-Lo
” - falling edge (from high to low state).
“
Lo
”, “
Hi
” - selection of state:
”
Lo
” - low,
“
Hi
“ - high.
Examples are shown in paragraph 8 on page 25.
7.2.5.
Menu “
diSPL”
This menu allows to set displaying formats of main timer and totalizer.
„C-diSP”
-
this parameter defines displaying format of main timer.
Possible values:
“
SEc
” - time displayed in format ”
seconds . milliseconds
”
“
h-m-S
” - time displayed in format ”
hours
. minutes . seconds . milliseconds
”
“
h-m
” - time displayed in format ”
hours
. minutes
(seconds are recalculated to
hours and minutes)
“h-h10”
- time displayed in format “
hours
. fractional part of hour
” .
20
Содержание SLC-94
Страница 35: ...User manual for TIMER SLC 94 35...