User manual for - TIMER SLC-94
„
C-PrEC
” - this parameter sets precision of main timer displayed time.
“
0.000
”, “
0.00
”, “
0.0
”, “
0.
” - from 1 ms to 1 sec respectively
This parameter do not concern formats : “h-m” lub “h-h10”.
Combinations of parameters
and
allow to set several formats and ranges
of main timer:
Displaying range
Format
The unit for last
displayed digit
„SEc”
„0.000”
000.000 ÷ 999.999
sec.millisec
1 millisecond
„SEc”
„0.00”
0000.00 ÷ 9999.99
sec.millisec
10 milliseconds
„SEc”
„0.0”
00000.0 ÷ 99999.9
sec.millisec
100 milliseconds
„SEc”
„0.”
000000. ÷ 999999.
sec.
1 second
„h-m-S”
„0.000”
0.00.000 ÷ 9.59.999
(max 10min)
min.sec.millisec
1 millisecond
„h-m-S”
„0.00”
00.00.00 ÷ 59.59.99
(max 60min)
min.sec.millisec
10 milliseconds
„h-m-S”
„0.0”
0.00.00.0 ÷ 9.59.59.9
(max 10hour)
hour.min.sec.millisec
100 milliseconds
„h-m-S”
„0.”
00.00.00. ÷ 99.59.59.
(max 100hour)
hour.min.sec.
1 second
„h-m”
do not
concern
0.00.00.0 ÷ 9999.59
(max godz)
hour.min..
1 minute
„h-h 10”
do not
concern
00.00.00. ÷ 99999.9
(max godz)
hours .fractional part of
hour
fractional part of hour
„t-diSP”
- t
his parameter defines displaying format of main timer. Possible values:
“
h-m-S
” - time displayed in format ”
hours
. minutes . seconds
”
“
h-m
” - time displayed in format ”
hours
. minutes
(seconds are recalculated to hours and minutes)
“h-h10” - time displayed in format “hours . fractional part of hour” .
These settings are corresponded to method of displaying of the result. Internal
precision of counting is invariable and equals 1ms.
7.2.6.
” PuSH
” menu
This parameter allows to enable/disable control of measurements via keyboard.
Following values are available:
“
oFF
” - control of measurements using local keyboard is disabled (this is default value)
“
on
” - control of measurements using local keyboard is enabled (control )
21