background image

293 Wright Street • Delavan, WI  53115

© 2013 

 

SIM820 (10/17/13)

SAFETY INFORMATION

Carefully read and follow all safety instructions in this 

manual and on pump.

This is the safety alert symbol. When you see this 

symbol on your pump or in this manual, look for one of 

the following signal words and be alert to the potential for  

personal injury!

warns about hazards that will cause serious 

personal injury, death or major property damage if ignored.

warns about hazards that can cause serious 

personal injury, death or major property damage if ignored.

warns about hazards that will or can cause 

minor personal injury or property damage if ignored.

The word NOTICE indicates special instructions which are 

important but not related to hazards.

1.  Read these rules and instructions carefully. Failure 

to follow them could cause serious bodily injury and/or 

property damage.

2.  Check your local codes before installing. You must 

comply with their rules.

Hazardous voltage. Can shock, burn or 

kill. During operation the pump is in water. To avoid fatal 

shocks, proceed as follows if pump needs servicing:

3.  Disconnect power to outlet box before unplugging pump.

4.  Unplug the pump before handling or servicing. 

5.  Take extreme care when changing fuses. Do not stand 

in water or put your finger in the fuse socket.

6.  Do not modify the cord and plug. When using the cord 

and plug, plug into a grounded outlet only. When wiring 

to a system control, connect the pump ground lead to 

the system ground.

7.  Do not run the pump dry. Dry running can overheat the 

pump (causing burns to anyone handling it), and will 

void the warranty. 

8.  The pump normally runs hot. To avoid burns when 

servicing pump, allow it to cool for 20 minutes after 

shut-down before handling it.

9.  The pump is permanently lubricated. No oiling or 

greasing is required in normal operation.

10.  Do not install the basin and pump in any location 

classified as hazardous by the United States National 

Electrical Code (NEC), or by the Canadian Electrical 

Code (CEC), where applicable.

PUMP SPECIFICATIONS

Power Supply Required ..................................... 115V, 60 Hz

Individual Branch Circuit Required ..........................15 Amps

Maximum Liquid Temperature ..........................120°F (50°C)

Discharge Adapter ..............................................  1-1/2” NPT

DESCRIPTION

The Simer Sump Pump System, is ideal for basement and 

cellar installations. It includes a submersible sump pump 

and a corrosion-resistant sump basin and lid. The pump 

features a flush-mount system for maximum discharge of 

the basin. All components of the sump pump system are 

pre-assembled at the factory for easy installation.

This submersible pump is designed for sump drainage, 

dewatering and flood control. The pump has built-in thermal 

overload protection and an automatic reset. The mechanical 

seal and sleeve bearings on the motor shaft are permanently 

lubricated. 

This system is designed for residential use only. The  

supplied hardware kit includes a rubber inlet hub and a  

cord grommet. No special tools or sealants are required.

NOTICE: This system is not designed for applications involving 

salt water or brine! Use with salt water or brine will void  

warranty.

PERFORMANCE

InStallatIon, operatIon, & partS Manual

Preplumbed Sump Pump System

GPH (LPH) AT TOTAL FEET (METERS) OF LIFT

No flow  

at height 

shown 

below

Model 5 (1.5 m) 10 (3 m) 15 (4.6 m) 20 (6.1 m)

23 ft

(7.0 m)

3985C

2,220

(8,404)

1,800

(6,814)

1,260

(4,770)

300

(1,136)

*For performance at maximum temperature see Catalog.

Содержание 3985C

Страница 1: ...ll void the warranty 8 The pump normally runs hot To avoid burns when servicing pump allow it to cool for 20 minutes after shut down before handling it 9 The pump is permanently lubricated No oiling o...

Страница 2: ...shock the power cord is a three wire conductor and includes a 3 prong grounded plug Plug the pump into a 3 wire grounded grounding type receptacle Connect the pump according to the NEC or CEC and loca...

Страница 3: ...of the assembly interfere with the float Operation Failure to make this operational check may lead to improper operation premature failure and flooding NOTICE The shaft seal depends on water for lubr...

Страница 4: ...open the pump further than removing the suction housing The pump motor housing contains a special lubricating oil which should be kept clean and free of water at all times The sump basin and cover pu...

Страница 5: ...ff of basin For parts or assistance call Simer Customer Service at 1 800 468 7867 1 800 546 7867 Key No Part Description Qty 3985C 1A Basin Cover Assembly Includes Nos 1 8 1 PW73 65P 1 Basin Cover 1 2...

Страница 6: ...fore handling pump or motor Check to be sure you have electrical power Check that water level in basin is high enough to activate switch or controller Check to be sure that the anti airlock hole in th...

Страница 7: ...applications Sewage Pumps DO NOT return a sewage pump that has been installed to your retail store Contact SIMER Customer Service Sewage pumps that have seen service and been removed carry a contamin...

Страница 8: ...8 For parts or assistance call Simer Customer Service at 1 800 468 7867 1 800 546 7867...

Страница 9: ...t de causer des blessures la personne qui la manip ulerait de plus cette pratique annule la garantie 8 Normalement la pompe est extr mement chaude lorsqu elle fonc tionne Pour ne pas se br ler si on d...

Страница 10: ...s cor dons lectriques Risque de secousses lectriques et d incendies S assurer que les renseignements indiqu s dans cette Notice concernant l alimentation lectrique tension hertz phase correspondent ex...

Страница 11: ...sant le col lecteur d eau et en observant le fonctionnement de la pompe sur un cycle complet S assurer que rien ne g ne le fonctionnement de l interrupteur 11 Pour le service des pi ces ou d assistanc...

Страница 12: ...ons du couvercle du collecteur et l aide de ses poign es sortir la pompe du collecteur NE D MONTER RIEN D AUTRE QUE le carter d aspiration de la pompe Le carter du moteur de la pompe contient une huil...

Страница 13: ...ntilation de 2 pouces 1 4 Rondelle plate 8 5 Boulon du collecteur 8 6 Bride de refoulement de 1 1 2 pouce 1 7 Bague d tanch it des cordons lectriques 1 8 Joint du couvercle 1 PW73 71 9 Bague d tanch i...

Страница 14: ...haut pour actionner l interrupteur flotteur ou le contr leur 4 S assurer que le trou d air perc dans le tuyau de refoulement de la pompe n est pas bouch 5 S assurer que l aspiration de la pompe l imp...

Страница 15: ...a t install e au d taillant Communiquer avec le service la client le de SIMER Les pompes d eaux d gout qui ont t utilis es puis retir es pr sentent un risque de contamination En cas de d faillance de...

Страница 16: ...16 Pour le service des pi ces ou d assistance appeler le service la client le Simer au 1 800 468 7867 1 800 546 7867...

Страница 17: ...ant a 8 La bomba generalmente est caliente durante su funcionamien to Para evitar quemaduras cuando se repare la bomba deje que se enfr e por 20 minutos despu s de haberla apagado y antes de manipular...

Страница 18: ...e corriente el ctrica de la instalaci n Instale la bomba conforme a todas las normas el ctricas que correspondan AVISO Se necesita una ventilaci n adecuada para impedir una pre si n negativa en el com...

Страница 19: ...ador Si se hace caso omiso a esta verificaci n existe el peligro de que ocurra un funcionamiento incorrecto una falla prematura e inundaci n 19 Por repuestos o ayuda llame al Departamento de Atenci n...

Страница 20: ...omento Es necesario proteger el compartimiento de recogida y la cubierta la bomba y las tuber as en caso de temperaturas heladas Si existe el peligro de que haya temperaturas heladas se deber drenar l...

Страница 21: ...e refuerzo del cord n 1 8 Aro de estanqueidad 1 PW73 71 9 Manguito de admisi n a presi n 1 10 Compartimiento de recogida 1 11 Bomba de sumidero 1 2975 REP 12 Tubo de descarga 1 U37 690P PIEZAS DE REPA...

Страница 22: ...activar el interruptor o el control 4 Verificar que el orificio de ventilaci n anti bolsas de aire en la descarga de la bomba no est obturado 5 Verificar que no haya bloqueo en la admisi n de la bomba...

Страница 23: ...comerciales o de alquiler Bombas cloacales NO devuelva una bomba cloacal que se haya instalado a su tienda minorista Comun quese con el Departamento de Atenci n al Cliente de SIMER Las bombas cloacale...

Страница 24: ...24 Por repuestos o ayuda llame al Departamento de Atenci n al Cliente de Simer 1 800 468 7867 1 800 546 7867...