69
ES
ENG
USER INSTRUCTIONS
WARNINGS
– In case of fault and/or incorrect equipment operation, deactivate it, without making any repairs or taking any direct action.
Apply only to qualified technical personnel.
– Boiler installation and any other assistance and/or maintenance activity must be carried out by qualified personnel per-
suant to Standard CEI 64-8. Under no circumstances, the devices sealed by the manufacturer can be tampered with.
– It is absolutely prohibited to block the intake grilles and the aeration opening of the room where the equipment is installed.
– The manufacturer shall not be held liable for any damage caused by improper use of the appliance.
– This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities,
or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance
by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
LIGHTING AND OPERATION
BOILER IGNITION (fig. 24)
The first ignition of the boiler must be car-
ried out by qualified technical personnel.
Successively, if it is necessary to start up
the boiler again, adhere strictly to the fol-
lowing instructions: open the gas tap to
allow the flow of the fuel and move the
main switch of the system to “ON”.
When fuel is fed to the boiler, a sequence of
checks will be carried out and the display
shows the normal condition of the functio-
ning, always indicating the pressure of the
system. If the blue luminous bar is on, this
indicates the presence of voltage.
Press the key
of the controls (pos. 2)
to activate the functioning. The display will
be as shown in the figure.
N.B.: To the first pressure the keys of the
controls (2) the display is illuminated, to
the successive pressure the operation
modality is active.
REGULATION OF THE WATER TEMPERA-
TURE FOR HEATING (fig. 25)
To set the temperature of the water for
heating, press the key
of the controls
(2). The first time the key is pressed, the
SET of heating circuit 1 is selected. The
second time it is pressed, the SET of hea-
ting circuit 2 is selected. The third time it is
pressed, the SET of heating circuit 3 is
selected (Three zones).
The display will be as shown in the figure.
Change the values with the key
and
.
Standard visualisation will return to the
display by pressing the key
again, or
after 10 seconds if no key is pressed.
REGULATION OF THE EXTERNAL
SENSOR (fig. 25/a)
If an external sensor is installed, the value
2
Fig. 24
Fig. 25
Fig. 25/a
2
Circuito
riscaldamento 2
Circuito
riscaldamento 3
(impianto tre
zone)
Heating circuit 2
Heating circuit 3
(Three zones)
Содержание MURELLE EQUIPE 220 BOX
Страница 1: ...MURELLE EQUIPE 220 330 440 550 BOX ErP Fonderie SIME S p A Cod 6322825 03 2016 ES ENG...
Страница 2: ......
Страница 76: ...76 NOTES...