41
ES
ENG
FR
1.3
TECHNICAL SPECIFICATIONS
MURELLE EQUIPE
220 BOX ErP
330 BOX ErP
440 BOX ErP
550 BOX ErP
Generators with a heat output kW 105.4
n°
2
3
4
5
Heat output
Nominal (80-60°C) (Pn max)
kW
210.8
316.2
421.6
527.0
Nominal (50-30°C) (Pn max)
kW
225.2
337.8
454.0
563.0
Minimum (80-60°C) (Pn min)
kW
20.8
20.8
20.8
20.8
Minimum (50-30°C) (Pn min)
kW
23.2
23.2
23.2
23.2
Heat input (*)
Nominal (Qn max - Qnw max)
kW
216
324
432
540
Minimum (Qn min - Qnw min)
kW
21.6
21.6
21.6
21.6
Min/max operating yield (80-60°C)
%
96.4/97.6
96.4/97.6
96.4/97.6
96.4/97.6
Min/max operating yield (50-30°C)
%
107.4/104.2
107.4/104.2
107.4/104.2
107.4/104.2
Operating yield at 30% (40-30°C)
%
105.4
105.4
105.4
105.4
Losses after shutdown to 50°C (EN 15502)
W
498
747
996
1245
Feeding tension
V-Hz
230-50
230-50
230-50
230-50
Absorbed power consumption (Qn max)
W
516
774
1032
1290
Absorbed power consumption (Qn min)
W
134
138
142
146
Absorbed power consumption C.H. pump
W
260 (130 x 2)
390 (130 x 3)
520 (130 x 4)
650 (130 x 5)
Electrical protection grade
IPX4D
IPX4D
IPX4D
IPX4D
Energy efficiency
Seasonal energy efficiency class of the heating system
A
A
A
A
Seasonal energy efficiency of the heating system
%
90
91
91
91
Sound power of the heating system
dB (A)
---
---
---
---
Single module temperature regulation
°C
20/80
20/80
20/80
20/80
Water content modules
l
36.3
55.9
72.6
92.2
Max operating pressure (PMS)
bar
5
5
5
5
Max operating temperature (T max)
°C
85
85
85
85
Exhaust temperature at max flow rate (80-60°C)
°C
64
64
64
64
Exhaust temperature at min flow rate (80-60°C)
°C
51
51
51
51
Exhaust temperature at max flow rate (50-30°C)
°C
45
45
45
45
Exhaust temperature at min flow rate (50-30°C)
°C
40
40
40
40
Smokes flow min/max
g/s
10.28/103.34
10.28/155
10.28/206.67
10.28/258.34
CO
2
at max/min flow rate (G20)
%
9.0/9.0
9.0/9.0
9.0/9.0
9.0/9.0
CO
2
at max/min flow rate (G31)
%
10.2/10.2
10.2/10.2
10.2/10.2
10.2/10.2
NOx measured
mg/kWh
24
24
24
24
Max. output pressure fumes manifold
Pa
375
375
375
375
Max. pressure independent fumes
Pa
428
428
428
428
PIN number
1312CM5621
1312CM5621
1312CM5621
1312CM5621
Category
II2H3P
II2H3P
II2H3P
II2H3P
Category in France
I2Er3P
I2Er3P
I2Er3P
I2Er3P
Type
B23-B53-B23P-B53P B23-B53-B23P-B53P B23-B53-B23P-B53P B23-B53-B23P-B53P
NOx emission class
5
5
5
5
Wight when empty
kg
380
615
760
995
Gas and nozzle pressure
Supply pressure (G20/G25)
mbar
20/25
20/25
20/25
20/25
Supply pressure (G31)
mbar
37
37
37
37
Number of nozzles
n°
2
3
4
5
Nozzle diameter (G20/G25)
ø
12.4
12.4
12.4
12.4
Nozzle diameter (G31)
ø
8.2
8.2
8.2
8.2
Consumption gas at nominal output (G20)
m
3
/h
22.84
34.26
45.68
57.10
Consumption gas at minimum output (G20)
m
3
/h
2.28
2.28
2.28
2.28
Consumption gas at nominal output (G31)
kg/h
16.76
25.14
33.52
41.90
Consumption gas at minimum output (G31)
kg/h
1.68
1.68
1.68
1.68
(*) Heat input of the heating system measured using lower heating value (LHV)
Содержание MURELLE EQUIPE 220 BOX
Страница 1: ...MURELLE EQUIPE 220 330 440 550 BOX ErP Fonderie SIME S p A Cod 6322825 03 2016 ES ENG...
Страница 2: ......
Страница 76: ...76 NOTES...
Страница 77: ...77 NOTES...
Страница 78: ...78 NOTES...
Страница 79: ......