TECHNICAL FEATURES
* With
∆
t 10°C
** With the sanitary water at inlet temperature 15°C - Boiler temperature 80°C
U
E
40
40
L
S4
R3
M2
H
50
A
B
=
=
C
40
C
1.2.1
D.H.W. storage tank BA
Fig. 1/a
RONDÒ - ESTELLE
BA tank
3
4
5
6
7
100
150
200
Output
Minimum
kW (kcal/h)
18,9 (16.300)
24,5 (21.000)
32,5 (28.000)
41,7 (35.900)
49,9 (42.900)
–
–
–
Maximum
kW (kcal/h) 23,5 (20.200)
31,3 (26.900)
40,0 (34.400)
48,1 (41.400)
57,5 (49.500)
–
–
–
Input
Minimum
kW (kcal/h)
21,1 (18.100)
27,2 (23.400)
36,0 (31.000)
46,1 (39.600)
55,0 (47.300)
–
–
–
Maximum
kW (kcal/h) 26,2 (22.500) 34,8 (29.900)
44,3 (38.100)
53,1 (45.700)
63,3 (54.400)
–
–
–
Sections
n°
3
4
5
6
7
–
–
–
Maximum water head
bar
4
4
4
4
4
–
–
–
Water content
l
12,8
16,8
20,8
24,8
28,8
–
–
–
Smokes loss of head
Minimum/Maximum
mbar
0,05/0,11
0,12/0,16
0,15/0,21
0,30/0,35
0,32/0,43
–
–
–
Water loss of head*
mbar
5
10
15
20
25
–
–
–
Combustion chamber pressure
mbar
–0,02
–0,02
–0,02
–0,02
–0,02
–
–
–
Suggested chimney depression
mbar
0,07/0,13
0,14/0,18
0,17/0,23
0,32/0,37
0,34/0,45
–
–
–
Smokes temperature
Minimum/Maximum
°C
160/185
160/185
160/185
160/170
160/170
–
–
–
Smokes flow
Minimum/Maximum
m
3
n/h
24,0/31,6
32,4/41,4
42,9/52,8
54,8/63,3
65,5/73,8
–
–
–
Smokes volume
dm
3
9
1
2
1
5
1
8
21
–
–
–
CO
2
%
12,5
12,5
12,5
12,5
12,5
–
–
–
C.H. adjustment range
°C
30÷85
30÷85
30÷85
30÷85
30÷85
–
–
–
D.H.W. adjustment range
°C
–
–
–
–
–
30÷65 30÷65 30÷65
D.H.W. flow rate
∆
t 30°C**
l/h
–
–
–
–
–
918
990
1308
D.H.W. tank capacity
l
–
–
–
–
–
100
150
200
D.H.W. maximum water head
bar
–
–
–
–
–
6
6
6
Weight
kg
109
135
161
186
212
82
102
122
BA 100 BA 150 BA 200
U
D.H.W. outlet
3/4”
3/4”
3/4”
C
Re-circulation
3/4”
3/4”
3/4”
E
D.H.W. inlet
3/4”
3/4”
3/4”
M2 D.H.W. tank flow
1”
1”
1”
R3 D.H.W. tank return
1”
1”
1”
S4 Drain cock
1/2”
1/2”
1/2”
BA 100 BA 150 BA 200
L ø mm
505
505
555
H mm
845
1175
1265
A mm
225
225
235
B mm
645
685
825
Содержание estelle