A E R O S T A T S E N T R Y
5 1 0 0 6 0 0 R e v . H
Aerostat Sentry
Ionizing Blower
INSTALLATION AND OPERATING INSTRUCTIONS
Страница 1: ...AEROSTAT SENTRY 5100600 Rev H Aerostat Sentry Ionizing Blower INSTALLATION AND OPERATING INSTRUCTIONS...
Страница 2: ...AEROSTAT SENTRY 5100600 Rev H TABLE OF CONTENTS 1 DESCRIPTION 3 2 SAFETY 4 3 SPECIFICATIONS 5 4 INSTALLATION 7 5 OPERATION 8 6 MAINTENANCE 9 7 REPLACEMENT PARTS 10 8 WARRANTY 11...
Страница 3: ...ield that injects alternating polarity ions into the airflow The shaped airflow exiting the Sentry carries these ions over a broad area for static elimination The ionizer of the Sentry features a bala...
Страница 4: ...m being returned should be shipped prepaid and packed to provide adequate protection 2 SAFETY NOTE Statements identified with a NOTE indicate precautions necessary to avoid potential equipment failure...
Страница 5: ...elocity Fan Speed 1 ft 2 ft 3 ft 4 ft Low 600 300 180 150 Medium 800 400 220 180 High 1000 500 250 200 Velocity in FPM measured at centerline of air stream Air Flow characteristics 3 x 6 Area Coverage...
Страница 6: ...t discharge time Fan Speed High 1 ft 2 ft 3 ft 4 ft 4 5 6 8 1 ft 1 5 2 5 4 5 5 Center Line 4 5 6 8 1 ft Fan Speed Medium 6 7 9 11 1 ft 1 7 3 5 5 7 Center Line 6 7 9 11 1 ft Fan Speed Low 8 9 10 12 1 f...
Страница 7: ...ration Plug the unit into a standard 2 terminal double grounded receptacle To set the unit up in a bench stand configuration secure the feet to the mounting yoke 1 Place the feet on a table top with t...
Страница 8: ...he Sentry produces an ionized air stream that covers a large area uniformly The time required to neutralize a static charge on an item in this area depends on many factors Two important factors are di...
Страница 9: ...ers 1 Grasp the emitter cleaner between thumb and forefinger 2 Sweep back and forth across the ionized air outlet Recommended frequency of cleaning is once a week The ionized air outlet should remain...
Страница 10: ...and again approach the surface with the tape If it has been neutralized it will not attract NOTE When performing this procedure do not use a plastic surface such as acrylic as the surface itself may b...
Страница 11: ...h 6 4670700 Brush 7 4401510 Ionizer Duct Standoff long 8 4401591 Ionizer Duct Standoff short 9 4103940 Line Cord Assembly 120 V 9 4104393 Line Cord Assembly 230 V 10 4610531 Rocker Switch 11 4610758 3...
Страница 12: ...any goods for any reason contact Simco Ion Customer Service at 215 822 6401 for a Return Authorization Number This number must accompany all returned items This warranty does not apply when the equip...