Receipt of equipment:

1.  Carefully remove the equipment from its carton.
2.  Empty the carton to ensure that small parts are not discarded.
3.  Inspect contents for damage that may have occurred during shipment.  If any 

damage has occurred, the local carrier should be notified at once.  A report 
should be forwarded to Simco-Ion, 2257 North Penn Road, Hatfield PA 
19440, and (215) 822-6401.

Return Shipments: 

Prior to returning goods, contact a Simco-Ion Customer Service Representative 
for a Return Authorization Number.  This number should be included on the 
packing list.  All correspondence should also reference the Return Authorization 
Number.  Any item being returned should be shipped prepaid and packed to 
provide adequate protection.

2. SAFETY

NOTE – 

Statements identified with a NOTE indicate precautions necessary 

to avoid potential equipment failure.

CAUTION – 

Statements identified with a CAUTION indicate potential 

safety hazards.

CAUTION – 

This equipment must be correctly installed and maintained.  

Adhere to the following notes for safe installation and operation.

1.  The unit is equipped with a grounding plug and must be plugged into a 

grounded receptacle.  Do not defeat the ground by modifying the plug or 
using an ungrounded adapter.  If an extension cord is necessary, use only a 
3-wire extension cord that provides grounding. 

2.  Internal repairs or servicing must be done by qualified service personnel
3.  Do not insert objects through intake or outlet grille.
4.  Do not operate unit in flammable or explosive atmospheres.

Содержание Aerostat Sentry 4003000

Страница 1: ...AEROSTAT SENTRY 5100600 Rev H Aerostat Sentry Ionizing Blower INSTALLATION AND OPERATING INSTRUCTIONS...

Страница 2: ...AEROSTAT SENTRY 5100600 Rev H TABLE OF CONTENTS 1 DESCRIPTION 3 2 SAFETY 4 3 SPECIFICATIONS 5 4 INSTALLATION 7 5 OPERATION 8 6 MAINTENANCE 9 7 REPLACEMENT PARTS 10 8 WARRANTY 11...

Страница 3: ...ield that injects alternating polarity ions into the airflow The shaped airflow exiting the Sentry carries these ions over a broad area for static elimination The ionizer of the Sentry features a bala...

Страница 4: ...m being returned should be shipped prepaid and packed to provide adequate protection 2 SAFETY NOTE Statements identified with a NOTE indicate precautions necessary to avoid potential equipment failure...

Страница 5: ...elocity Fan Speed 1 ft 2 ft 3 ft 4 ft Low 600 300 180 150 Medium 800 400 220 180 High 1000 500 250 200 Velocity in FPM measured at centerline of air stream Air Flow characteristics 3 x 6 Area Coverage...

Страница 6: ...t discharge time Fan Speed High 1 ft 2 ft 3 ft 4 ft 4 5 6 8 1 ft 1 5 2 5 4 5 5 Center Line 4 5 6 8 1 ft Fan Speed Medium 6 7 9 11 1 ft 1 7 3 5 5 7 Center Line 6 7 9 11 1 ft Fan Speed Low 8 9 10 12 1 f...

Страница 7: ...ration Plug the unit into a standard 2 terminal double grounded receptacle To set the unit up in a bench stand configuration secure the feet to the mounting yoke 1 Place the feet on a table top with t...

Страница 8: ...he Sentry produces an ionized air stream that covers a large area uniformly The time required to neutralize a static charge on an item in this area depends on many factors Two important factors are di...

Страница 9: ...ers 1 Grasp the emitter cleaner between thumb and forefinger 2 Sweep back and forth across the ionized air outlet Recommended frequency of cleaning is once a week The ionized air outlet should remain...

Страница 10: ...and again approach the surface with the tape If it has been neutralized it will not attract NOTE When performing this procedure do not use a plastic surface such as acrylic as the surface itself may b...

Страница 11: ...h 6 4670700 Brush 7 4401510 Ionizer Duct Standoff long 8 4401591 Ionizer Duct Standoff short 9 4103940 Line Cord Assembly 120 V 9 4104393 Line Cord Assembly 230 V 10 4610531 Rocker Switch 11 4610758 3...

Страница 12: ...any goods for any reason contact Simco Ion Customer Service at 215 822 6401 for a Return Authorization Number This number must accompany all returned items This warranty does not apply when the equip...

Отзывы: