5
A E R O S T A T S E N T R Y
5 1 0 0 6 0 0 R e v . H
3. SPECIFICATIONS
Unit Part Number:
4003000 4003143
Line Voltage:
115 VAC
60 Hz.
230 VAC
50 Hz
Current Draw:
Fan low
0.5 Amp
0.25 Amp
Fan medium
0.7 Amp
0.35 Amp
Fan high
0.9 Amp
0.45 Amp
Air Volume Output:
Fan Speed
Flow
Low
70 CFM
Medium
95 CFM
High
120 CFM
Air Velocity:
Fan Speed
1 ft.
2 ft.
3 ft.
4 ft.
Low
600
300
180
150
Medium
800
400
220
180
High
1000
500
250
200
Velocity in FPM measured at centerline of air stream
Air Flow characteristics:
3’ x 6’ Area Coverage
Operating Temperature:
32° F (0° C) - 122° F (50° C)
Ozone Production:
0.005 ppm measured 6” in front of unit. Test conducted in accordance with EPA EQOA-0577-019
using Dasibi Ozone Monitor model 1003AH
Audible Noise:
Fan Speed
Audible Noise
Low
52 dB
Medium
58 dB
High
64 dB
Noise measured 2 ft. from unit