Simco-Ion Aerostat Sentry 4003000 Скачать руководство пользователя страница 3

3

A E R O S T A T   S E N T R Y

5 1 0 0 6 0 0   R e v .   H

1. DESCRIPTION

The Sentry ionized air blower produces an air

fl

 ow that is rich in positive and 

negative ions.  Directing the air

fl

 ow on an object that has a static charge will 

neutralize the charge.  If the object has a positive static charge, it will draw 
negative ions from the air

fl

 ow.  If the object has a negative static charge, it will 

draw positive ions from the air

fl

 ow.  The ions are attracted to the oppositely 

charged object and neutralize the charge on the object.
The Sentry uses a three-speed blower to produce a uniform air

fl

 ow.  The air is 

drawn into the unit through slots.  The air exits the blower and enters a duct, 
which shapes and ionizes the air

fl

 ow.  The ionizer uses a transformer, which 

produces high voltage AC.  This transformer is inherently current limited for 
safety.  The transformer output also contains a current limiting resistor, which 
provides redundant safety and enhances the ionization stability.  The high voltage 
AC is applied to a row of stainless steel ion emitters, which results in an intense 
alternating electric 

fi

 eld at the tip of the emitters.  It is this intense electric 

fi

 eld 

that injects alternating polarity ions into the air

fl

 ow.  The shaped air

fl

 ow exiting 

the Sentry carries these ions over a broad area for static elimination.
The ionizer of the Sentry features a balancing circuit.  The balancing circuit works 
by isolating the transformer secondary from electrical ground.  This results in the 
equal production of positive and negative ions.  The Sentry also features a built-in 
emitter cleaner.  Cleaning the emitters on a weekly basis prevents the buildup of 
airborne debris to which all electrical ionizers are prone.  This keeps your Sentry 
working in top form for the life of the unit.
The Sentry is designed for use where static electricity creates problems.  The 
Sentry is particularly well suited to neutralize charges on three-dimensional 
objects such as parts emerging from a molding process.  It is also suitable for 
neutralization over a large area such as plastic sheet fabrication and forming.
The Sentry blower is designed for superior performance:

• 

Rapidly neutralizes static charges

• 

Covers an extended area with ionized air

• 

Three speed fan with wide range of air flow

• 

Bench stand mount

• 

Built-in emitter cleaner

• 

Durable, electrically grounded steel enclosure

The Sentry is listed by UL and CUL (equivalent to CSA); the 230V Sentry is 
marked CE.  The system must be properly installed and maintained.

 

Содержание Aerostat Sentry 4003000

Страница 1: ...AEROSTAT SENTRY 5100600 Rev H Aerostat Sentry Ionizing Blower INSTALLATION AND OPERATING INSTRUCTIONS...

Страница 2: ...AEROSTAT SENTRY 5100600 Rev H TABLE OF CONTENTS 1 DESCRIPTION 3 2 SAFETY 4 3 SPECIFICATIONS 5 4 INSTALLATION 7 5 OPERATION 8 6 MAINTENANCE 9 7 REPLACEMENT PARTS 10 8 WARRANTY 11...

Страница 3: ...ield that injects alternating polarity ions into the airflow The shaped airflow exiting the Sentry carries these ions over a broad area for static elimination The ionizer of the Sentry features a bala...

Страница 4: ...m being returned should be shipped prepaid and packed to provide adequate protection 2 SAFETY NOTE Statements identified with a NOTE indicate precautions necessary to avoid potential equipment failure...

Страница 5: ...elocity Fan Speed 1 ft 2 ft 3 ft 4 ft Low 600 300 180 150 Medium 800 400 220 180 High 1000 500 250 200 Velocity in FPM measured at centerline of air stream Air Flow characteristics 3 x 6 Area Coverage...

Страница 6: ...t discharge time Fan Speed High 1 ft 2 ft 3 ft 4 ft 4 5 6 8 1 ft 1 5 2 5 4 5 5 Center Line 4 5 6 8 1 ft Fan Speed Medium 6 7 9 11 1 ft 1 7 3 5 5 7 Center Line 6 7 9 11 1 ft Fan Speed Low 8 9 10 12 1 f...

Страница 7: ...ration Plug the unit into a standard 2 terminal double grounded receptacle To set the unit up in a bench stand configuration secure the feet to the mounting yoke 1 Place the feet on a table top with t...

Страница 8: ...he Sentry produces an ionized air stream that covers a large area uniformly The time required to neutralize a static charge on an item in this area depends on many factors Two important factors are di...

Страница 9: ...ers 1 Grasp the emitter cleaner between thumb and forefinger 2 Sweep back and forth across the ionized air outlet Recommended frequency of cleaning is once a week The ionized air outlet should remain...

Страница 10: ...and again approach the surface with the tape If it has been neutralized it will not attract NOTE When performing this procedure do not use a plastic surface such as acrylic as the surface itself may b...

Страница 11: ...h 6 4670700 Brush 7 4401510 Ionizer Duct Standoff long 8 4401591 Ionizer Duct Standoff short 9 4103940 Line Cord Assembly 120 V 9 4104393 Line Cord Assembly 230 V 10 4610531 Rocker Switch 11 4610758 3...

Страница 12: ...any goods for any reason contact Simco Ion Customer Service at 215 822 6401 for a Return Authorization Number This number must accompany all returned items This warranty does not apply when the equip...