Lamp button is also used to set the level of the air duct at closed
position. After activating the air duct by pressing the S key for 3
seconds, you shall enter the closed position setting mode by
pressing the Lamp button for 3 seconds. “C” and “L” symbols are
displayed respectively on the screen, meaning CLOSE.
Desired closed position is selected with the air duct facing down by
pressing the Fan button or with the air duct facing up by pressing
the Timer button. If the setting mode is active and you shall not
make any fine settings, you may press the Lamp key for 3 seconds
to save the position and exit the setting mode. You shall exit from
the setting mode and the settings made shall be saved to perma-
nent memory if you do not press the Lamp and “On/Off” keys for
about 15 seconds in the closed position setting mode.
Closed Position Levels:
1st Level
“C”, “L” and “1” shall be displayed respectively
2nd Level
“C”, “L” and “2” shall be displayed respectively
3rd Level
“C”, “L” and “3” shall be displayed respectively
4th Level
“C”, “L” and “4” shall be displayed respectively
5th Level
“C”, “L” and “5” shall be displayed respectively
6. Level
“C”, “L” and “6” shall be displayed respectively
Closed position of the air flow mechanism may be
set in 6 different levels. It is set as the 1st level as
default.
Fan Button
This is the speed (rpm) control key. Your appliance shall switch up
to the next level (1-2-3-4) whenever you press this button. When
you press the fan key on the 4th speed setting, which is the max-
imum speed, your appliance shall switch back to the 1st speed set-
ting, which is the minimum speed (4-1-2-3…). Appliance switches
to off (‘0’) position when fan key is pressed for 2 seconds.
Timer Button
Timer function shall be activated when you the timer key for 1
second. The speed displayed on the screen (1-2-3-4) starts to
flash, and it continues to flash in this way until the timer function
ends. If the motor is on when this key is pressed, it shall turn off
automatically after 15 minutes. Moreover, if the lighting lamps are
on when this key is pressed, they shall turn off automatically at the
end of the timer (after 15 minutes), too. However, if the lighting
lamps are turned on after pressing this key, they shall not be
turned off automatically, you need to turn them off manually. Activa-
tion of this key shall not affect the operation of the air duct. If the air
duct is on, it shall continue to operate until it is turned off manually
or automatically.
Closed Position Fine Setting Mode
How to operate the product
24.07.2020
24
Содержание SCV 1160-50 HV HERMOD
Страница 5: ...2 Technical drawing 500 500 81 121 460 114 100 Fig 2 Technical drawing 24 07 2020 5...
Страница 6: ...500 700 81 121 660 114 100 Fig 3 Technical drawing 24 07 2020 6...
Страница 19: ...F g 14 Adjustment of a r flow 24 07 2020 19 Balanc ng d agram for forced vent lat on...
Страница 21: ...F g 16 Adjustment of a r flow 24 07 2020 21 D mens on ng d agram for forced vent lat on...