Assembly instructions

SCV 1160-50 RF HERMOD
SCV 1160-50 HV HERMOD
SCV 1160-70 RF HERMOD
SCV 1160-70 HV HERMOD
Read this manual carefully before installation / commissioning

Содержание SCV 1160-50 HV HERMOD

Страница 1: ...Assembly instructions SCV 1160 50 RF HERMOD SCV 1160 50 HV HERMOD SCV 1160 70 RF HERMOD SCV 1160 70 HV HERMOD Read this manual carefully before installation commissioning...

Страница 2: ...en_US MANUFACTURER Merzifon OSB AMASYA Silverline IMPORT Jilmas Group Nordic ApS Eli Christensens Vej 90 7430 Ikast Denmark Telephone 45 70104014 Fax 45 70131389 Internet www silverline dk 24 07 2020...

Страница 3: ...he package 13 7 Assembly Installation of the product 14 7 1 Height recommended 14 8 Installation of hood 15 8 1 Connection of central ventilation 15 9 Klemens Ba lant s 16 10 Adjustment of air flow 17...

Страница 4: ...1 Product overview 1 Control Panel 2 Filter 3 Mounting plate 4 Lighting 1 2 3 4 Fig 1 Product overview 24 07 2020 4...

Страница 5: ...2 Technical drawing 500 500 81 121 460 114 100 Fig 2 Technical drawing 24 07 2020 5...

Страница 6: ...500 700 81 121 660 114 100 Fig 3 Technical drawing 24 07 2020 6...

Страница 7: ...therwise high heat may cause deformation of certain parts of the product n Turn off the hobs before removing the cookware from there n Do not leave hot oil on the stove Pans with hot oil can ignite sp...

Страница 8: ...has the correct height above the hob read the recommended height in the manual Ask if necessary fire authority in your municipality about local laws and regulations for this n The hood s exhaust must...

Страница 9: ...s a risk of poisoning to per sons staying near this airflow Fig 4 Therefore adequate intake of fresh air should always be ensured DANGER Fire Hazard If the device is not cleaned in accordance with the...

Страница 10: ...t Repairs should always be performed by an authorized or approved specialist In the event of a fault or damage to the device dis connect the fuse or disconnect the device from the wall outlet and call...

Страница 11: ...teel MAY NOT come in contact with detergents Grease and oil must be removed with a damp wet cloth or special steel care product Improper maintenance can provoke rust IR or other marks on the surface T...

Страница 12: ...bove 55 degrees Sink You can use a special oil solvent to remove stubborn dirt You can get this solvent from an authorized dealer Soften the grease filters in warm water with dish soap Use a brush for...

Страница 13: ...6 The content of the package 1 3 2 4 Fig 6 1 Product 2 2x 10 mm Rawplugs 3 2x 5 5x60 Screw 4 User Manual The content of the package 24 07 2020 13...

Страница 14: ...and screws Use rawl plugs and screws that fit the material the hood is to be mounted in Vent We recommend the use of a muffler see possibly under accesso ries at www silverline dk at the hood to dampe...

Страница 15: ...nsert the screws 1 The distance between the screw head and the wall must be 5mm Fig 8 Hang the hood in the screws at points A and B and tighten the screws 8 1 Connection of central ventilation 1 Flue...

Страница 16: ...DC PWM OUTPUT 12V BLUE DC PWM OUTPUT 12V GREY DC MOTOR 220V BLACK DC MOTOR 220V BROWN 220V AC BLUE 220V AC YELLOW EC 12V BLUE EC 12V BROWN 220V EC BLUE 220V EC BROWN 220V AC BLUE 220V AC GROUND J1 CON...

Страница 17: ...just the product to the desired condition use the setting tables Sizing information Balancing information Sizing data For calculations 50 Pa 100 Pa Basic ventilation 20 l s 72 m3 h 20 l s 72 m3 h Pres...

Страница 18: ...m3 h 40 l s 144 m3 h Pressure 50 Pa 100 Pa Damper pos t on F 5 F 3 3 Sound pressure Lpa 25 dBA 32 dBA The product factory sett ngs are based on 50 pA Depend ng on the pressure be ng measured the tabl...

Страница 19: ...F g 14 Adjustment of a r flow 24 07 2020 19 Balanc ng d agram for forced vent lat on...

Страница 20: ...ressure level db A s measured n a room equ pped w th sound absorpt on of 10 m Sab n For calculat ons D mens on ng d agram and data are used Adjustment of a r flow 24 07 2020 20 Balanc ng d agram for s...

Страница 21: ...F g 16 Adjustment of a r flow 24 07 2020 21 D mens on ng d agram for forced vent lat on...

Страница 22: ...F g 17 Lp A Sound pressure level db A s measured n a room equ pped w th sound absorpt on of 10 m Sab n Adjustment of a r flow 24 07 2020 22 S z ng d agram for bas c vent lat on...

Страница 23: ...s which is the same as the cur rent one You shall exit from the setting mode and the settings made shall be saved to permanent memory if you do not press the buttons S and On Off for about 15 seconds...

Страница 24: ...ctively Closed position of the air flow mechanism may be set in 6 different levels It is set as the 1st level as default Fan Button This is the speed rpm control key Your appliance shall switch up to...

Страница 25: ...n Off keys for about 15 seconds in the open position setting mode Open Position Fine Setting Mode If the open position setting mode of the air duct is turned on and if you have reached the desired lev...

Страница 26: ...3 Check that it is the right model with width color internal external motor etc 4 We recommend a professional for the installation of the hood NB We do not take responsibility for products that have...

Страница 27: ...0w GU10 light sources To find out how many watts of power the product s light sources are on this can be found inside the product on the serial number label To remove the light sources the grease filt...

Страница 28: ...Suction on the following pages My grease filters are discolored Filter cleaner in dish washer When cleaning grease filters in the dishwasher it is per fectly normal for the filters to discolour This h...

Страница 29: ...cleaned regu larly otherwise they will result in a reduced power until they are cleaned again In our quest for product improvements JG Nordic Silverline reserves the right to change product specifica...