12V Lithium Jump Starter & Powerbank
684786
15
silverlinetools.com
Smart Jump Start Protector Unit (Fig. II)
Green and Red LED Status
Condition Description
Action
Solid Green LED
Cable/clamp polarity correct,
the Lithium Jump Starter
voltage is above 11V, and
vehicle battery is above low
limit threshold
Can now attempt to jump
start the vehicle
Green LED blinking and
Smart Jump Start Protector
Unit beeping
Vehicle battery is low
Press Jump Start Protector
Boost Button. Wait until
Green LED is solid then,
within 30 seconds, attempt
to jump start the vehicle
Solid Red LED and Smart
Jump Start Protector Unit
beeping
Connection is incorrect.
Cable/clamps are in reverse
polarity, a vehicle battery
short has been detected,
or incorrect Lithium Jump
Starter voltage
Do not attempt to jump start
the vehicle. Disconnect High
Current Connector Plug and
remove clamps from the
vehicle’s battery terminals.
Reconnect clamps to the
vehicle’s battery in correct
polarity (see ‘Jump starting
a 12V vehicle’) then connect
the High Current Connector
Plug to the Lithium Jump
Starter
Note:
The source of this
problem must be found and
resolved before any more
attempts are made to jump
start the vehicle using the
Lithium Jump Starter
No LEDs or beeping
Vehicle’s battery may be
damaged
Disconnect High Current
Connector Plug and remove
clamps from the vehicle’s
battery terminals. Reconnect
in correct polarity to the
vehicle’s battery terminals
and Lithium Jump Starter. If
there is no solid Green LED,
press the Boost Button.
WARNING:
If the Lithium Jump Starter becomes warm to the touch at any time, disconnect the
Lithium Jump Starter from the cables then allow to cool fully before re-attempting the next jump
start.
Maintenance
Note:
The Lithium Jump Starter comes equipped with an internal rechargeable lithium polymer
battery. This battery is not consumer replaceable, and must be disposed of when the battery can no
longer hold charge. Correct charging practices will prolong the life of the battery.
• Charge the device fully at least once every 3–4 months if not used regularly to maintain the life
of the lithium polymer battery
Cleaning
• Keep your Lithium Jump Starter clean. Always clean dust/particles away
• Use a soft brush or dry cloth to clean the device
• Make sure that the positive and negative lead clamps are kept clean. Dirty electrical contacts will
severely impair the performance of this product
• A soft wire brush can be used to clean the clamps
• NEVER use water or alcohol-based cleaners to clean the device
Storage
• Store fully charged. The unit will hold charge for 6 to 12 months, but should always be charged
before the next use after being stored for a long period of time
• Store this tool carefully in a secure, cool, dry place (-10°–30°C / 14°–86°F) out of the reach of
children
• If storing in a moving vehicle, ensure that the unit, particularly the Lithium Polymer Battery Pack
(1), cannot move around freely
Disposal
Always adhere to national regulations when disposing of power tools that are no longer functional
and are not viable for repair.
• Do not dispose of power tools or other waste electrical and electronic equipment (WEEE) with
household waste
• Contact your local waste disposal authority for information on the correct way to dispose of power
tools
Troubleshooting
Problem
Possible cause
Solution
Lithium Jump Starter
will not switch OFF when
pressing the Power
Button (3)
The automatic switch off
Leave the device unplugged
from cables and all other
devices for approximately 10
seconds, and the unit should
switch off automatically
The Lithium Jump Starter
will not switch ON when
pressing the Power Button
The Lithium Polymer Battery
Pack (1) has no charge
Charge the unit from a
power supply into the
Quick Charge Input Port
(4). If after charging the
device does not switch on,
it may have reached the
end of the battery life and
will need to be disposed
of in accordance with local
authorities (see ‘Disposal’)
During charging, the
Lithium Jump Starter
stops charging and begins
beeping
There is a problem with
the charging procedure;
the Lithium Polymer
Battery Pack has detected
a problem
1. Press and hold the Power
Button for 10–30 seconds
to force the continuation
of charging and possibly
correct the charging issue
2. After pressing and
holding the Power Button,
disconnect the power supply
and allow the Lithium Jump
Starter to reset
3. Reconnect the power
supply to the Lithium Jump
Starter to see if the unit will
charge again normally
4. If the unit again
discontinues charging
and begins beeping,
IMMEDIATELY DISCONNECT
the power supply and
discontinue use. Consult
an authorised Silverline
technician
Note: After pressing and
holding the Power Button
during this process, the
LED Light (5) will come
on, which is normal. After
disconnecting the charger,
the LED Light may be turned
OFF (see ‘Using the Torch/
Strobe/SOS LEDs’) before
reconnecting the charger
The Lithium Polymer Battery
Pack becomes hot to touch
during use/begins to swell
The Lithium Polymer Battery
Pack is faulty
IMMEDIATELY DISCONNECT
the power supply/cables and
discontinue use. Consult
an authorised Silverline
technician
684786_Manual.indd 15
21/02/2019 12:19
Содержание 684786
Страница 2: ...2 1 2 3 4 5 6 7 8 11 12 10 9 8 8 684786_Manual indd 2 21 02 2019 12 19...
Страница 3: ...silverlinetools com 3 18 19 20 16 17 21 13 14 15 9 684786_Manual indd 3 21 02 2019 12 19...
Страница 10: ...10 684786_Manual indd 10 21 02 2019 12 19...
Страница 16: ...GB 16 684786_Manual indd 16 21 02 2019 12 19...
Страница 54: ...54 Notes 684786_Manual indd 54 21 02 2019 12 19...
Страница 55: ...silverlinetools com 55 Notes 684786_Manual indd 55 21 02 2019 12 19...