Fault
Cause
Remedy
The suction power
is too weak.
The dust container
3
is
full.
Empty the dust container
3
.
The HEPA dust filter
4
is
dirty.
Clean the HEPA dust filter
4
.
The suction opening
9
is blocked.
Turn off the appliance, pull out
the
plug from the wall socket
and remove the blockage.
The UV-C lamp
8
does not light up.
The automatic switch-off
device of the UV-C lamp
8
has been activated.
Check the safety switches
0
left and right (see section
Safety switches
).
The UV-C lamp
8
or
appliance is defective.
Contact Customer Service (see
section
Service
).
The vibration
head
7
does not
vibrate.
The vibration function is
not switched on.
Press the vibration button
w
.
An unpleasant
odour escapes
from the appliance
during suction.
Odours often develop
when new appliances
are used for the first time.
The smell should disappear
after the appliance has been
used a few times.
The appliance is
defective.
Switch off the appliance, pull
out the power plug
from the
socket and contact Customer
Service (see section
Service
).
Appendix
Technical data
Power supply
220 – 240 V ∼ (alternating current), 50 / 60 Hz
Power consumption
300 W
Protection class
II / (double insulation)
Light bulb
6 W, G5, UV-C
Classification of the UV-C
lamp risk group
Risk group 3
NOTE
►
No user action is required to switch the product between 50 and 60 Hz.
The product adapts automatically to either 50 or 60 Hz.