AN332
Rev. 0.8
135
Command 0x14. GET
_
INT
_
STATUS
Updates bits 6:0 of the status byte. This command should be called after any command that sets the STCINT or
RSQINT bits. When polling this command should be periodically called to monitor the STATUS byte, and when
using interrupts, this command should be called after the interrupt is set to update the STATUS byte. The CTS bit
(and optional interrupt) is set when it is safe to send the next command. This command may only be set when in
powerup mode.
Available in: All
Command arguments: None
Response bytes: None
Command
Response
Command 0x40. AM
_
TUNE
_
FREQ
Tunes the AM/SW/LW receive to a frequency between 149 and 23 MHz in 1 kHz steps. In AM only mode, the valid
frequency is between 520 and 1710 kHz in 1 kHz steps. The CTS bit (and optional interrupt) is set when it is safe to
send the next command. The ERR bit (and optional interrupt) is set if an invalid argument is sent. Note that only a
single interrupt occurs if both the CTS and ERR bits are set. The optional STC interrupt is set when the command
completes. The STCINT bit is set only after the GET_INT_STATUS command is called. This command may only
be sent when in powerup mode. The command clears the STC bit if it is already set. See Figure 29, “CTS and STC
Timing Model,” on page 244 and Table 50, “Command Timing Parameters for the AM Receiver,” on page 247.
AM: LO frequency is 45 kHz above RF for RF frequencies < 1000 kHz and 45 kHz below RF for RF frequencies
> 1000 kHz. For example, LO frequency is 945 kHz when tuning to 900 kHz.
Note:
FAST bit is supported in Si473x-C40 and later devices and Si474x devices (AMRX component 3.0 or later).
ANTCAP bits are supported in AMRX component 2.0 or later (all devices except Si4730-A10).
Available in: All
Command arguments: Five
Response bytes: None
Command
Bit
D7
D6
D5
D4
D3
D2
D1
D0
CMD
0
0
0
1
0
1
0
0
Bit
D7
D6
D5
D4
D3
D2
D1
D0
STATUS
CTS
ERR
X
X
RSQINT
X
X
STCINT
Bit
D7
D6
D5
D4
D3
D2
D1
D0
CMD
0
1
0
0
0
0
0
0
ARG1
0
0
0
0
0
0
0
FAST
ARG2
FREQ
H
[7:0]