AN332
Rev. 0.8
181
Response
Command 0x14. GET
_
INT
_
STATUS
Updates bits 6:0 of the status byte. This command should be called after any command that sets the STCINT,
RSQINT, SAMEINT (Si4707 only), or ASQINT bits. When polling this command should be periodically called to
monitor the status byte, and when using interrupts, this command should be called after the interrupt is set to
updated the status byte. The CTS bit (and optional interrupt) is set when it is safe to send the next command. This
command may only be sent when in powerup mode.
Available in: All
Command arguments: None
Response bytes: One
Command
Response
Bit
D7
D6
D5
D4
D3
D2
D1
D0
STATUS
CTS
ERR
X
X
RSQINT
SAMEINT
ASQINT
STCINT
RESP1
0
0
0
0
0
0
0
0
RESP2
PROPV
H
[7:0]
RESP3
PROPV
L
[7:0]
RESP
Bit
Name
Function
1
7:0
Reserved
Always returns 0.
2
7:0
PROPV
H
[7:0]
Property Value High Byte.
This byte in combination with PROPV
L
will represent the requested
property value.
3
7:0
PROPV
L
[7:0]
Property Value High Byte.
This byte in combination with PROPV
H
will represent the requested
property value.
Bit
D7
D6
D5
D4
D3
D2
D1
D0
CMD
0
0
0
1
0
1
0
0
Bit
D7
D6
D5
D4
D3
D2
D1
D0
STATUS
CTS
ERR
X
X
RSQINT
SAMEINT
ASQINT
STCINT