A N 3 3 2
214
Rev. 0.8
Command 0x14. GET_INT_STATUS
Updates bits 6:0 of the status byte. This command should be called after any command that sets the ASQINT bit.
When polling this command should be periodically called to monitor the STATUS byte, and when using interrupts,
this command should be called after the interrupt is set to update the STATUS byte. The CTS bit (and optional
interrupt) is set when it is safe to send the next command. This command may only be set when in powerup mode.
Available in: All
Command arguments: None
Response bytes: None
Command
Response
Command 0x61. AUX_ASRC_START
Starts sample rate conversion in signal processing module. The CTS bit (and optional interrupt) is set when it is
safe to send the next command. The ERR bit (and optional interrupt) is set if an invalid argument is sent. Note that
only a single interrupt occurs if both the CTS and ERR bits are set. This command may only be sent when in
powerup mode.
Available in: All
Command arguments: One
Response bytes: None
Command
Response
Bit
D7
D6
D5
D4
D3
D2
D1
D0
CMD
0
0
0
1
0
1
0
0
Bit
D7
D6
D5
D4
D3
D2
D1
D0
STATUS
CTS
ERR
X
X
X
X
ASQINT
X
Bit
D7
D6
D5
D4
D3
D2
D1
D0
CMD
0
1
1
0
0
0
0
1
Bit
D7
D6
D5
D4
D3
D2
D1
D0
STATUS
CTS
ERR
X
X
X
X
ASQINT
X