Diagnostics
007-4564-001
119
The offline diagnostics display test status information as they run. If the diagnostics
complete testing without detecting errors, the output is similar to the following example:
Starting diagnostic program...
Press <Esc> to return to the menu.
SMDK SGI Version 6.152 TEST built 08:41:26 AM Mar 6, 2003
smdk loading io discovery code...
smdk loading launcher code...
smdk>
sMDK Diagnostic Launcher: Version 2.0
Built 00:42:56 Mar 6 2003
Setting up diagnostics.....
term none
Starting diagnostics.....
Testing CACHE.......... PASSED
Testing DIMM................................................. PASSED
Testing IO................... PASSED
FINISHED
Reseting...
resetting the system...
If the launcher detects an error, it displays a
FAILED
status message for the hardware it is
testing and stops testing. If any of the components do not pass the offline diagnostics,
contact your service representative.