17
OPERATION
!
WARNING! Shock hazard. Risk of injury to persons.
The RPS generates high AC voltage which can cause injury or death. Only a
qualified electrician should open the RPS for servicing.
WARNING! Shock hazard. Risk of injury to persons.
To avoid the possibility of electrical shock, make sure all AC electrical cords
connected to the RPS are in good condition.
WARNING: Explosion or fire hazard. Risk of injury to persons.’
Do not operate the RSG in areas that may contain explosive gas.
CAUTION! Possible Damage to RPS
Locate the RPS in a cool, dry location. Do not block the Vents as they are used to
cool the inverter. Provide at least 1 foot of clearance between the cooling vents
and any obstruction. The RPS operates most efficiently at room temperature
(around 78 F).
Operating Range
Controller Voltage
Approximate Battery Charge
26.4
90% Upper Battery Voltage -
Solar Charging Disabled
26.2
80%
26.0
70%
25.6
60%
25.4
50%
25.0
40%
24.8
30% AC inverter/AC Outlet re-enabled
24.6
20%
24.2
10% Lower Battery Voltage –
AC inverter disabled