PIPE
WORK
All pipe work should be either copper, PVC or CPVC (Do not use
flexible pipes). Hangers should not be less than three feet apart to
prevent pipe rattling.
DISCHARGE
Never discharge directly into an open drain, fixture, manhole or
rainwater drainpipe. It is illegal for it constitutes a health hazard.
Direct connections into sanitary waste systems only, shall be
acceptable.
FREEZING
Ensure all pipe work susceptible to freezing is adequately
insulated or heated. In unheated buildings, the toilet, piping and
macerating unit must be properly winterized with “RV or
plumbers” anti-freeze or drained completely.
ELECTRICITY
The macerating system must be connected to a Ground Fault
Circuit Interrupter (GFCI).
Before attempting any maintenance or
servicing, the unit must be disconnected from the power source.
EASY ACCESS
The unit should be accessible and removable in the event of
maintenance being required. During the installation a full-port
ball valve should be installed at the base of any vertical
discharge pipe work from the unit to allow easy service of the
unit.
BENDS
Where possible long sweeping bends should be used. Do not use
short elbows. If sweeping 90° elbows are not available use two
45° elbows to make a 90° turn.