Y AXIS SENSOR REPLACEMENT (FRONT PANEL SENSOR)
1) turn off the machine and disconnect from the power supply.
2) gain access to the top compartment (Ch. 7.3).
3) gain access to the bottom compartment (Ch. 7.4).
4) use pliers to disconnect the Y axis sensor connection (K) from the board.
5) loosen the screw (S2) and remove together with the sensor and its support (S3). Remove the worn sensor and
replace with a new one.
Fit the support with the new sensor, regulating it until it almost touches the upper bracket
6) securing the nut (K1)
7) connect the sensor connector (K).
8) proceed to Maintenance > Machine zeroes (Ch. 5.8.2 ).
9) replace the bottom plate.
Fig. 91
Fig. 92
Operating Manual
UC199
Copyright Silca 2012
81
Содержание UC 199
Страница 1: ...Operating Manual Original Instructions D441737XA vers 1 0 EN UC199 UC199 UC199 Japan UC199 Japan...
Страница 81: ...Fig 82 Fig 83 Operating Manual UC199 Copyright Silca 2012 77...
Страница 86: ...Fig 93 Operating Manual UC199 Copyright Silca 2012 82...
Страница 94: ...Operating Manual UC199 Copyright Silca 2012 90...
Страница 96: ...ELECTRICAL DIAGRAMS Operating Manual UC199 Copyright Silca 2012 92...
Страница 97: ...Operating Manual UC199 Copyright Silca 2012 93...
Страница 98: ...Operating Manual UC199 Copyright Silca 2012 94...
Страница 99: ...Operating Manual UC199 Copyright Silca 2012 95...
Страница 100: ...Operating Manual UC199 Copyright Silca 2012 96...
Страница 101: ...Terminal board connection Operating Manual UC199 Copyright Silca 2012 97...
Страница 102: ...UC199 KEY CUTTING MACHINE OPTIONAL LOADER UNIT Operating Manual UC199 Copyright Silca 2012 98...
Страница 103: ...Operating Manual UC199 Copyright Silca 2012 99...