Operating manual - English
DELTA 2000 AY
Copyright Silca 1 998
15
7.3
Tracer point replacement
To replace the tracer point (F), proceed as follows (fig. 16):
WARNING:
unplug the machine from the mains.
1) loosen and remove the tracer point locking screw (F1).
2) remove the tracer point.
3) fit the new tracer point.
4) re-gauge the machine as described in (Ch. 6, page 11).
Fig. 16
7.4
Replacing the fuses
WARNING:
unplug the machine from the mains.
1) detach the wiring from the machine plug;
2) turn the key-cutting machine so that the fuse box is easily reached;
3) remove the fuse box placed below the power inlet (K) (fig. 17);
4) replace the fuses (L);
5) close the fuse box and connect the power cable.
WARNING:
the fuses must both be of the same type (rapid) and with the same amps (3,15 Ampere)
Fig. 17
F1
F
K
L