Siko MSK+MB Скачать руководство пользователя страница 7

MSK+MB...

Datum 22.02.2000

Art.Nr. 78334

Z.Nr. 8668027

Änd.Stand 67/00

7

ENGLISH

1. Safety information

In order to carry out installation correctly, we
strongly recommend this document is read very
carefully. This will ensure your own safety and
the operating reliability of the device.

• Your device has been quality controlled, te-
sted and is ready for use. Please respect all
warnings and information which are marked
either directly on the device or in this document.

• Warranty can only be claimed for components
supplied by SIKO GmbH. If the system is used
together with other products, the warranty for the
complete system is invalid.

• Repairs should be carried out only at our
works. If any information is missing or unclear,
please contact the SIKO sales staff.

2. Identification

Magnetic strip: identification by printing on the
strip.

Example: Magnetic strip "MB"

MB

MB5

MB20

accuracy

0.1/0.05 0.1/0.05 0.1

pole pitch

5

5

5

strip width

10

5

20

User Information

MSK+

MB,MB5,MB20

Magnetic Sensor / Magnetic Strip

Magnetic sensor: The particular type of unit and
type number can be seen from the identification
plate. Type number and the corresponding varia-
tions are indicated in the delivery documentati-
on.

e.g.    MSK-0023

type number
type of unit

3. Installation

The unit sshould only be used according to the
protection level provided. Protect the system, if
necessary, against environmental influences
such as sprayed water, dust, knocks, extreme
temperatures, solvents.

3.1 Mounting the magnetic strip

The mounting surface / measuring track must be
flat.  Buckles or bumps will lead to measuring
inaccuracies.

For applications which do not allow properly glueing of the
magnetic strip,  it can be inserted into a profile rail (accessory)
- eg.  rail type PS or PS1 thus forming a compact mounting

unit.

For technical reasons the strip should be approx.
25 mm longer than the actual measuring di-
stance.

Attention! To guarantee optimal adhesion oil,
grease dust etc. must be removed by using
cleansing agents which evaporate without lea-
ving residues. Suitable cleansing agents are eg.
ketones (acetone) or alcohols; Messrs. Loctite
and 3M can both supply such cleansing liquid.
Make sure that the surface to be glued is dry and
apply the strip with maximum pressure. Glueing
should preferably be undertaken at tempera-
tures between 20 to 30° C and in dry atmosphere.

Advice! When applying long pieces of magnetic
strip do not immediately remove the complete
protective foil, but rather peel back a short part
from the end sufficient to fix the strip. Now align
the strip. As the protective strip is then peeled
back and out press the tape firmly onto the
mounting surface. A wall paper roller wheel could
be used to assist in applying pressure onto the
magnetic strip when fixing it in position.

Mounting steps (see fig. 1)

• Clean mounting surface (1) carefully.

• Remove protective foil  (2) from the adhesive
side of the magnetic strip (3).

• Stick down the magnetic strip (4).

pole pitch: 5mm
accuracy: 0.1mm
serial number

1

0

NNNN           5000

Содержание MSK+MB

Страница 1: ...t mit h chstm gli chem Anpressdruck zu verkleben Die Verkle bungstemperatur ist optimal zwischen 20 und 30 C in trockenen R umen Tip Bei Verklebung langer B nder sollte die Schutzfolie des Klebebandes...

Страница 2: ...llte dass das Magnetband vollst ndig darin eingebettet werdenkann Abb 2 Abb 3 Abb 4 Abb 5 3 2 MontageMagnetsensor DerMagnetsensor kanndurchVerwendungvon 2SchraubenM3 berdie 3 5mmDurchgangs l cherbefes...

Страница 3: ...it Funkenl schglie dern beschaltet sein Spannungsversorgung UB 10 30 VDC optional 4 75 5 25 VDC 5 Anschlussarten Die Steckerbelegungen der verschiedenen An schlussartenwerdennachfolgendbeschrieben Ach...

Страница 4: ...Mit einfa chen Hilfsmitteln besteht die M glichkeit das Magnetbandzutrennenundwiederzusammen zusetzen Es ist jedoch selbst bei exakter Vorgehenswei se damit zu rechnen dass die Genauigkeit an der Tren...

Страница 5: ...agnetbandwurdefalschmontiert akti ve Seite nach unten Kap 3 1 Zum Schutz des Magnetbandes wurde nicht das mitgelieferte Abdeckband verwendet Das Abdeckband muss nichtmagnetisierbar sein Der Sensor ist...

Страница 6: ...6 MSK MB Datum 22 02 2000 Art Nr 78334 Z Nr 8668027 nd Stand 67 00...

Страница 7: ...influences such as sprayed water dust knocks extreme temperatures solvents 3 1 Mounting the magnetic strip Themountingsurface measuringtrackmustbe flat Buckles or bumps will lead to measuring inaccura...

Страница 8: ...cts the magnetic strip The groove should be deep enough to totally embed the magnetic strip Fig 2 Fig 3 Fig 4 Fig 5 3 2 Mounting the sensor Use the two M3 screws to fix the magnetic sensor via the 3 5...

Страница 9: ...r coils must be linked with spark suppression Supplyvoltage UB 10 to 30 V d c option 4 75 to 5 25 V d c 5 Connection methods Below description of the pin connection for the different connection method...

Страница 10: ...rejoined using standard tools But however carefully this is done the accuracy of the strip at the join will be impaired error of at least 0 1 0 2 mm The following tools accessories are requi red magne...

Страница 11: ...Magnetic strip incorrectly mounted active surface must be mounted towards the sensor see chapter 3 1 Use of foreign protective strip Must always benon magnetic Sensor not or incorrectly connected pin...

Страница 12: ...Nr 8668027 nd Stand 67 00 Postanschrift Postal address Postfach1106 D 79195Kirchzarten Werk Factory Weihermattenweg2 D 79256Buchenbach Telefon Phone 0 76 61 3 94 0 Telefax Fax 0 76 61 3 94 388 Intern...