• Join the two ends closely together and add the
cover strip.
7. Maintenance
We recommend cleaning the magnetic strip’s
surface from time to time with a soft rag. This
avoids dirt (dust, chips, humidity ...) sticking to
the strip.
8. Trouble shooting
Below are some typical errors which may occur
during installation and operation:
• Magnetic strip incorrectly mounted (active
surface must be mounted towards the sensor)
(see chapter 3.1)
• Use of foreign protective strip. Must always
be non-magnetic.
• Sensor not or incorrectly connected (pin con-
nection, see chapter 5).
• Tolerance for the gap between magnetic sen-
sor and magnetic strip not observed over the
total travel distance. Sensor touches strip (see
fig. 6)
• Cable squeezed / interrupted / cut by sharp
edges.
• Sensor’s active side not mounted towards the
magnetic strip (see fig. 6). The active side is
marked by the label "scale side".
• Sensor has not been aligned according to
chapter 3.2.