![Siko MSA501 Скачать руководство пользователя страница 43](http://html1.mh-extra.com/html/siko/msa501/msa501_user-manual_1270545043.webp)
Communication via
CAN bus (CANopen)
MSA501
Date: 12.10.2018
Art. No. 88734
Mod. status 330/18
Page 43 of 51
Subindex
02h
Description
Flag 0 Register
Access
ro
PDO-Mapping
no
Data type
UNSIGNED 8
Default
20h
EEPROM
no
Data content
Bit 7, 6
Not used
Bit 5
Fine value of filtering: 0 = OFF; 1 = ON
Bit 4…2
Not used
Bit 1
Counting direction : 0 = Up; 1 = Down
Bit 0
Resolution: 0 = 10µm; 1 = 5µm
Subindex
03h
Description
Flag 1 Register
Access
ro
PDO-Mapping
no
Data type
UNSIGNED 8
Default
43h
EEPROM
no
Data content
Bit 7
External Reset (/MCLR) Pin bit
Bit 6
Software Reset (Instruction) Flag bit
Bit 5
Software Enable/Disable of WDT bit
Bit 4
Watchdog Timer Time-out Flag bit
Bit 3
Wake-up from Sleep Flag bit
Bit 2
Wake-up from Idle Flag bit
Bit 1
Brown-out Reset Flag bit
Bit 0
Power-on Reset Flag bit
Subindex
04h
Description
Flag 2 Register
Access
ro
PDO-Mapping
no
Data type
UNSIGNED 8
Default
0h
EEPROM
no
Data content
Bit 7
Trap Reset Flag bit
Bit 6
Illegal Opcode or Uninitialized W Access Reset Flag bit
Bit 5…2
Not used
Bit 1
Configuration Mismatch Flag bit
Bit 0
Voltage Regulator Standby During Sleep bit