![Siko MSA501 Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/siko/msa501/msa501_user-manual_1270545028.webp)
Communication via
CAN bus (CANopen)
MSA501
Date: 12.10.2018
Art. No. 88734
Mod. status 330/18
Page 28 of 51
5.6.2.6
1008h: Manufacturer Device Name
Object 1008h indicates the device name. Since the latter comprises 6 data bytes, normal
transfer is required for reading the SDO (see chapter
5.4.1.2: Normal Request/Response
Subindex
00h
Description
Device name in ASCII notation
Access
Const
PDO-Mapping
no
Data type
Visible_String
Default
MSA501
EEPROM
no
Byte 0
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
4Dh
("M")
53h ("S") 41h ("A") 35h ("5") 30h ("0") 31h ("1") 00h ("0")
5.6.2.7
1009h: Manufacturer Hardware Version
Object 1009h indicates the hardware version.
Subindex
00h
Description
Hardwareversion in ASCII-Zeichen
Access
Const
PDO-Mapping
no
Data type
Visible_String
Default
V001
EEPROM
no
Data content
Byte 0
Byte 1
Byte 2
Byte 3
56h ("V")
30h ("0")
30h ("0")
31h ("1")
5.6.2.8
100Ah: Manufacturer Software Version
Object 100Ah indicates the software version of the device.
Subindex
00h
Description
Software version in ASCII notation
Access
Const
PDO-Mapping
no
Data type
Visible_String
Default
V001
EEPROM
no
Data content
Byte 0
Byte 1
Byte 2
Byte 3
56h ("V")
31h ("0")
30h ("0")
30h ("1")