Functional Description
AP10S
Date: 12.05.2020
Art. No. 90304
Mod. status 110/20
Page 8 of 44
2.3.1
Key lock and enable time
The key access to the chain dimension function and calibration can be generally blocked with
the parameters KeyCalibration and KeyIncremental (see chapter
). The time during which
the button must be pressed until you can enter the menu can be set in the Options menu.
Access via keys to the changeable device parameters can only be obtained after entering the
PIN. This can be defined using the parameter PINChange (see chapter
3
Functional Description
3.1
Operating modes
The following position-dependent operating modes are differentiated:
Absolute position
and
the position-independent operating mode
Alpha-numeric display
.
Operating mode Absolute position Alpha-numeric Display
Line 1
Actual value
(ActualValue)
Target value 1 (DisplayData)
Line 2
Target value
(TargetValue)
Target value 2 (TargetValue)
Table 1: Display with different operating modes
3.1.1
Absolute position operating mode
The measured absolute position value is calculated depending on the parameters
and
and displayed as actual value. The actual value (
of higher-level control can be provided via the interface and a target value can be set as a
default. The target value must be set to valid in the ControlWord (
3.1.1.1
Positioning
Target window:
A target window is formed to be able to define a tolerance range.
Target window =
Example Position monitoring:
TargetWindow = 5
TargetValue = 100