5.1.2.1
Process data output (master
device)
Sub-
index
Name
Bit
offset
Bit
length
Data
type
Comment
1
TargetValue
0
32
Signed-
Integer
Displayed value in bottom
row (4 figures right)
2
TargetValueLeft
32
16
Unsigned
Integer
Displayed value in bottom
row (2 figures left)
3
bc00_Reserved
48
1
Bool
Used in AbsoluteMode
4
bc01_Reserved
49
1
Bool
If true DisplayData is
active
5
bc02_DisplayDataActive
50
1
Bool
6
bc03_DisplayRange
51
1
Bool
If true display range is
extended
7
bc04_GuardingBit
52
1
Bool
Communication guarding
8
bc05_ErrorAck
53
1
Bool
If true the actual error is
acknowledged
9
bc06_TargetValueAckMode
54
1
Bool
If true TargetValue
becomes acknowledged
10
bc07_TargetValueTypeSelect 55
1
Bool
Format of TargetValue
11
bc08_DisplayDataTypeSelect 56
1
Bool
Format of DisplayData
12
bc09_TargetValueActive
57
1
Bool
If true TargetValue is
active
13
bc10_DisplayDataAckMode
58
1
Bool
If true DisplayData
becomes acknowledged
14
bc11_Led1Green
59
1
Bool
If true LED is on.
Function controlled via
Parameter LEDMode
15
bc12_Led1Red
60
1
Bool
see bc11
16
bc13_Led2Green
61
1
Bool
see bc11
17
bc14_Led2Red
62
1
Bool
see bc11
18
bc15_LedBlinking
63
1
Bool
If true LEDs are blinking
when on
Table 24: Process data output in Alphanumeric display operating mode
5.1.2.2
Process data input (device
master)
Sub-
index
Name
Bit
offset
Bit
length
Data
type
Comment
1
PositionValue
0
32
Signed-
Integer
Absolute position value
2
Reserved
32
16
-
3
bs00_Reserved
48
1
Bool
Used in AbsoluteMode
4
bs01_Reserved
49
1
Bool
Used in AbsoluteMode