IO-Link
AP10S
Date: 12.05.2020
Art. No. 90304
Mod. status 110/20
Page 37 of 44
5.1.1
Process data in Absolute position operating mode
Sub-index Significance
(Absolute Position operating mode)
Bit offset Octet
Length
In
Out
1
PositionValue
TargetValue
0
4 … 7
32
2
Reserved
Reserved
32
2 … 3
16
3 … 18
ControlWord
StatusWord
48
0 … 1
16
Table 20: Process data definition
5.1.1.1
Process data output (master
device)
Sub-
index
Name
Bit
offset
Bit
length
Data
type
Comment
1
TargetValue
0
32
Signed-
Integer
Absolute target value
2
Reserved
32
16
-
Used in DisplayMode
3
bc00_CalibrationExecute
48
1
Bool
If true calibration
becomes executed
4
bc01_Reserved
49
1
Bool
5
bc02_Reserved
50
1
Bool
Used in DisplayMode
6
bc03_DisplayRange
51
1
Bool
If true display range is
extended
7
bc04_GuardingBit
52
1
Bool
Communication guarding
8
bc05_ErrorAck
53
1
Bool
If true the actual error is
acknowledged
9
bc06_Reserved
54
1
Bool
Used in DisplayMode
10
bc07_Reserved
55
1
Bool
Used in DisplayMode
11
bc08_Reserved
56
1
Bool
Used in DisplayMode
12
bc09_TargetValueActive
57
1
Bool
If true TargetValue is
active
13
bc10_Reserved
58
1
Bool
14
bc11_Led1Green
59
1
Bool
If true LED is on. Function
controlled via Parameter
LEDMode
15
bc12_Led1Red
60
1
Bool
see bc11
16
bc13_Led2Green
61
1
Bool
see bc11
17
bc14_Led2Red
62
1
Bool
see bc11
18
bc15_LedBlinking
63
1
Bool
If true LEDs are blinking
when on
Table 21: Process data output in Absolute position operating mode