Parameter
AP10S
Date: 12.05.2020
Art. No. 90304
Mod. status 110/20
Page 23 of 44
IO-Link
Data type
SignedInteger32
Access
rw
Index
69
Sub-index
0
Datastorage
no
Value range
-2147483648 ... 2147483647
Default
0
Display
Value range
-199999 ... 999999
4.1.4
ActualValue
General characteristics
EEPROM
no
Unit
-
IO-Link
Data type
SignedInteger32
Access
ro
Index
68
Sub-index
0
Datastorage
no
Value range
-2147483648 ... 2147483647
Default
0
Display
Value range
-199999 ... 999999
4.1.5
DisplayData
General characteristics
EEPROM
no
Unit
-
Value range
6 character
Default
-
IO-Link
Data type
OctetString6
Access
rw
Index
95
Sub-index
0
Datastorage
no